User's Manual
User Manual VC-EVCC
© 2021 Vector Informatik GmbH Version 1.3.0 100
Manual Configuration
Reprogramming is also possible without CANoe/CANalyzer. In this case, the following
CAN Messages (UDS/ TP) must be sent on the diagnostic CAN (CAN0) manually:
CAN-Identifier:
Tester --> VC-EVCC, Request: 0x610
VC-EVCC --> Tester, Response: 0x612
Tester --> Functional: 0x614
1. Extended Session:
Request: 02 10 03 FF FF FF FF FF
Response: 06 50 03 00 32 01 F4 FF
2. Tester Present:
Request: 02 3E 00 FF FF FF FF FF
Response: 02 7E 00 FF FF FF FF FF
Caution
The message “Tester Present” has to be sent cyclically in order to keep the VC-EVCC
in the extended session. Otherwise the extended session will be terminated after
approximately 4 – 5 seconds.
3. Plug and Charge:
XX:
- 0x00: Plug and Charge is deactivated
- 0x01: Plug and Charge is activated
Request: 04 2E FD 26 XX FF FF FF
Response: 03 6E FD 26 FF FF FF FF
Note
In some cases the response message might include the value “AA” instead of “FF”.
In order to read the present configuration of Plug and Charge, the following communication
has to be executed.
4. Read Plug and Charge configuration:
Request: 03 22 FD 26 FF FF FF FF
Response: 04 62 FD 26 XX FF FF FF