User's Manual
VCom Inc.
TRI1819 Manual; ml_tri1819_02(Feb 2005)
Approved: C.H.
7
1.3 Specifications
Subscriber Transceiver Specifications
TRANSMIT SPECIFICATIONS
IF Input Frequency 27 to 42 MHz
Automatic Mute Threshold Level -47 dBm
Automatic Mute Response Time < 2 microseconds
RF Frequency Range 1870 to 1885 MHz (Block B)
Rated Output Power +33 dBm EIRP
Integrated Gain 30 dB ± 1 dB
Gain Stability ±2 dB over temperature (-45 to +55ºC)
Spectral Mask FCC CFR 47 Part 24
Phase Noise <-85 dBc / Hz at 10 kHz
<-45 dBc integrated over 20 kHz to 2.5 MHz
Frequency Setting and Stability ±5.5 kHz
Frequency Stability over 10 years ±15 kHz
RECEIVE SPECIFICATIONS
RF Frequency Range 1950 to 1965 MHz (Block B)
Frequency Response (any 6 MHz band) ±0.5 dB
IF Output Frequency Range 227 to 242 MHz
Noise Figure <6.0 dB typical
Integrated Gain 41 dB
Input Third Order Intercept Point -10 dBm at LNA input
Phase Noise <-85 dBc / Hz at 10 kHz
<-45 dBc integrated over 20 kHz at 2.5 MHz
Frequency Setting and Stability ±5.5 kHz
Frequency Stability over 10 years ±15 kHz
GENERAL
IF Connector F female, 75 ohms
IF Return Losses >10 dB
Power Requirement +10.8 to +28 VDC
Power Consumption 12 W maximum
Operating Temperature Range -45 to +55ºC
Mounting Pole Mount (1” to 1.75” (25mm to 44mm) diameter)
Antenna Gain 15 dBi
Antenna Beamwidth 33° typical
Dimensions 12” x 12” x 3” (305mm x 305mm x 75 mm) maximum
Weight 6 lbs. (2.7 kg)
Specifications subject to change without notice.