User's Manual
VCom Inc.
TRI1819 Manual; ml_tri1819_02(Feb 2005)
Approved: C.H.
14
2.4 Waterproofing Connections
This will provide moisture protection and keep the connections tight. VCom has provided a 6-inch length of rubber
self-amalgamating sealing tape to use on the TRI1819 F-connector.
Step 1
Use a 6” section of rubber sealing tape. Starting at the TRI1819 end, stretch the tape and wrap it around the
connector as close as possible to the wall of the TRI1819. Overlap the tape by approximately one-half of its width
so that it can form a seal with itself. Extend the wrapping to approximately one-inch past the end of the connector.
Step 2
Cover the sealing tape with electrical tape (not provided). Start approximately one inch further down the cable, and
stretch the tape, overlapping by one-half. Wrap to the TRI1819 end and without breaking the tape, wrap back down
to the cable end.