INSTALLATION AND OPERATION GUIDE FOR SYSTEM OPERATORS
Proprietary to VCom Inc. All rights reserved. No part of this publication may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation or adaptation) without written permission from VCom Inc. VCom Inc. reserves the right to revise this publication and to make changes in content from time to time without obligation on the part of VCom Inc. to provide notification of such revision or change. VCom Inc.
Thank-you for purchasing this product and welcome to VCom! You have chosen an innovative broadband wireless solution from a leading technology design center in the ongoing TV & data delivery revolution. No doubt you’ve been thinking that the future of your television delivery system includes new technologies such as Digital TV, Internet Over Cable, Wireless Cable.
SAFETY PRECAUTIONS 1. Before installing and operating this equipment, read all Safety, Installation and Operating sections. Retain this manual for future reference. 2. Follow all instructions — Failure to do so may result in damage to the unit or severe personal injury. 3. The user should not attempt servicing. There are no user serviceable parts inside. Refer all servicing to factory qualified personnel. 4.
INDEX 1.0 GENERAL INFORMATION ........................................................................................................................ 6 1.1 Functional Overview..................................................................................................................................................6 1.2 Module Features ........................................................................................................................................................6 1.
1.0 GENERAL INFORMATION 1.1 Functional Overview The VCom TRI1819 is an outdoor RF transceiver for use in broadband wireless systems. The TRI1819 combines a low noise downconverter, high power upconverter, antenna and high rejection duplexer to offer a fully integrated solution for 1.9 GHz subscriber terminals.
1.3 Specifications Subscriber Transceiver Specifications TRANSMIT SPECIFICATIONS IF Input Frequency Automatic Mute Threshold Level Automatic Mute Response Time RF Frequency Range Rated Output Power Integrated Gain Gain Stability Spectral Mask Phase Noise 27 to 42 MHz -47 dBm < 2 microseconds 1870 to 1885 MHz (Block B) +33 dBm EIRP 30 dB ± 1 dB ±2 dB over temperature (-45 to +55ºC) FCC CFR 47 Part 24 <-85 dBc / Hz at 10 kHz <-45 dBc integrated over 20 kHz to 2.5 MHz ±5.
2.0 INSTALLATION 2.1 Unpacking the Unit Carefully remove the equipment from its packing material and set it on a solid surface, such as a table or desk. If it appears damaged in any way, notify the carrier, and keep all packing materials for inspection by the carrier’s agent. 2.
DIAGRAM 2.2A: LL-BRACKET ORIENTATION Once the L-bracket is in place, the unit can be mounted to the pole. The pole catch, V-bolt and L-bracket are oriented as shown in Diagram 2.2B. VCom Inc. TRI1819 Manual; ml_tri1819_02(Feb 2005) Approved: C.H.
DIAGRAM 2.2B: TRI1819 MOUNTED TO POLE Vertical Alignment Horizontal Alignment STEP 2 – Position V-bolt and pole catch around pole To attach the TRI1819 to the pole, first position the pole catch over the threads of the V-bolt and hold against the pole with one hand. VCom Inc. TRI1819 Manual; ml_tri1819_02(Feb 2005) Approved: C.H.
STEP 3 – Position TRI1819 against pole Using the other hand, bring the TRI1819 up to the pole catch and grab V-bolt, pole catch and L-bracket in a single hand. Ensure that the pole is inside the “L” of the L-bracket and not on the outside of the L. This is necessary to maintain antenna alignment during high winds.
2.3 Connection to the Power Inserter and Cable Modem Connections to the TRI1819 are made as shown in Diagrams 2.2B and either 2.3A or 2.3B depending on which power supply and inserter came with the TRI1819. Please note: 1) Connect the TRI1819 F-Connector to the power inserter, located indoors with the cable modem. The power inserter is then connected to the Cable Modem, only after the antenna is aligned.
DIAGRAM 2.3B: CONNECTION TO CABLE MODEM VIA POWER INSERTER USING CPE POWER SUPPLY & INSERTER VCom Inc. TRI1819 Manual; ml_tri1819_02(Feb 2005) Approved: C.H.
2.4 Waterproofing Connections This will provide moisture protection and keep the connections tight. VCom has provided a 6-inch length of rubber self-amalgamating sealing tape to use on the TRI1819 F-connector. Step 1 Use a 6” section of rubber sealing tape. Starting at the TRI1819 end, stretch the tape and wrap it around the connector as close as possible to the wall of the TRI1819. Overlap the tape by approximately one-half of its width so that it can form a seal with itself.
When done, the connection should be tightly wrapped with tape, with a good seal to the cable. VCom Inc. TRI1819 Manual; ml_tri1819_02(Feb 2005) Approved: C.H.
3.0 ALIGNING THE ANTENNA 3.3.1 Signal Strength and Alignment When power is first applied an audible signal (beep) will occur. Faster beeping indicates higher signal strength. Adjust the unit first panning left and right, then up and down until the rate of beeping is maximized. If the unit is difficult to tilt or turn, loosen the locknuts on the V-bolts slightly. If the beep rate is very quick, the beeps will continue to be heard for ~3mins and then stop.
4.0 WARRANTY AND SERVICE POLICIES 4.1 Warranty Statement VCom warrants its products to be free from defects in workmanship or materials for a period of two years. The warranty begins on the date of the original shipment from VCom to its customer. No claim may be allowed for expenses incurred in installation or use. No other expressed or implied warranties shall apply to the goods sold.
4.3 Repair Charges and Warranty Exemptions Items returned beyond the warranty period or items that do not qualify for warranty service are subject to additional out-of-warranty repair charges. Descriptions of these charges and warranty exemptions are below: 1) Repair turnaround time is typically 5-14 business days after receipt of the item at VCom. A Flat Rate Repair Charge will apply to all out-of-warranty items. Flat Rate Repair Charges are subject to change without notice.
150 Cardinal Place Saskatoon, Saskatchewan S7L 6H7 Canada Tel: (306) 955-7075 Fax: (306) 955-9919 www.vcom.com sales@vcom.