User's Manual
obr5000b_ml_r01_sdApproved: D.W.
3-8
Step 2 Once you have made the correct configuration settings, click the Submit button at the bottom of the window.
Step 3 To apply the Radio Configuration, click Apply Configuration from the menu options. The configuration area
displays a list of changes made. Click Yes to apply the changes.
Step 4 To save configuration changes to the radio, click Reboot from the menu options. The configuration screen
displays the following:
Click Yes to confirm the reboot.
3.6 Establishing a Link
Before you can establish the link between the base station and the subscriber station(s), ensure that the equipment is
set up as follows.
• The NMS, base station, subscriber station, and one or more host computers are physically connected and powered
up as shown in
Figure 3-1.
• The base station network and antenna have been configured as described in this manual.
• The subscriber station is powered up and connected to the host computers and the Downlink/Uplink frequency is
set to the same frequency as the base station transmit frequency.
• Host computers should be assigned static IP addresses.
NOTE
For more information about how to set up and configure VistaMAX components, see Finding Related
Documentation, on page iv. Documentation is available for download from the FTP site or by contacting Vecima
Networks.
To establish the link between the base station and subscriber station:
Step 1 Set up and configure your VistaMAX system.
Step 2 Power up all the units.
Step 3 The subscriber station should complete network entry and establish a link to the base station in 1-2 minutes.
Transmit Feed
Loss
The loss measured in dB
resulting from the transmission
feed wiring.
Type the value in the field
provided.
Customer specific
Uplink Target
Receive Level
This is the Uplink Rx level
which all Subscriber Stations
will strive to meet in dB
Enter the value into the blank
field
0 dB
Antenna Type There are two optional external
antenna connections. This
setting controls which
connector is active.
Select the radio button that
corresponds to the antenna
connector you want to make
active.
Customer specific
Data Encryption The Data payload is encrypted
using 128 bit 3DES and AES.
Click the drop-down menu
arrow and select on or off.
Off - data not
encrypted
Parameter Description Procedure Default