User's Manual

ma4367_ml_03_sd Approved: B.G. 32
Vecima Networks Inc.
Example: *999<sp>A<sp>RTD<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
OE - Enable Output
Description: Turns on the Output from the specified module.
Parameters: None
Example: *999<sp>A<sp>OE<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
OD - Disable Output
Description: Turns off the Output from the specified module.
Parameters: None
Example: *999<sp>A<sp>OD<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
LE - Enable Local Control
Description: Enables local control of the MA4367 system. The module address must indicate a valid module even though the
command does not change any module settings.
Parameters: None
Example: *999<sp>A<sp>LE<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
LD - Disable Local Control
Description: Disables local control of the MA4367 system. The module address must indicate a valid module even though the
command does not change any module settings.
Parameters: None
Example: *999<sp>A<sp>LD<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
SU - Status Unit Request
Description: The Status Unit Request command returns the factory model and revision history for the specified module. The
detailed contents of the reply are shown in the response section.
Parameters: None
Example: *999<sp>A<sp>SU<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
If the response is OK, then the following parameters will also be returned in the order shown below. (Note: X may be
replaced by any valid character. All other characters will be as shown).
T
ABLE 6.5.1A : RESPONSE PARAMETERS FOR STATUS UNIT REQUEST
Parameter (Units) Format Example
Model XXXXXXXXXXX Upconverter
Module SN XXXXXXX 0123456
Hardware Revision XXX 010 (i.e. Rev 1.0)
Microcontroller Revision XXX 010 (i.e. Rev 1.0)
PLD Revision XXX 010 (i.e. Rev 1.0)