User's Manual

ma4367_ml_03_sd Approved: B.G. 28
Vecima Networks Inc.
MA4061B Command Codes
FL = Load Frequency IAS = Set IF AGC Threshold
AI = Set IF Attenuation IAE = Enable IF AGC Threshold
AR = Set RF Attenuation IAD = Disable IF AGC Threshold
OE = Enable Output RTS = Set RF Threshold
OD = Disable Output RTD = Disable RF Threshold
ITS = Set IF Threshold RTE = Enable RF Threshold
ITD = Disable IF Threshold SU = Unit Status Request
ITE = Enable IF Threshold LE = Enable Local Control
LD = Disable Local Control
MA4070C Command Codes
OE = Enable Output FPHS = Forward Power High Set
OD = Disable Output FPHE = Forward Power Hi Enable
SU = Unit Status Request FPHD = Forward Power High Disable
SC = Configuration Status Request FPLS = Forward Power Low Set
LE = Enable Local Control FPLE = Forward Power Low Enable
LD = Disable Local Control FPLD = Forward Power Low Disable
RPS = Reverse Power Threshold Set
RPE = Reverse Power Threshold Enable
RPE = Reverse Power Threshold Disable
CRC = CRC-16 checksum (3 characters)
The checksum is preferred, but not required. If the checksum is used, the first character is an ASCII “V” followed by the low and high
bytes respectively of the computed CRC 16 checksum (the checksum characters are not necessarily ASCII). The checksum is to be
computed on all characters after the initial <start> character up to, and including, the first “V” character in the CRC section. If the
checksum is not used, the 3 characters should be ASCII “NNN” (they must be uppercase).
PARM is one or more characters, and is command specific.