User's Manual
ma4367_ml_03_sd Approved: B.G. 22
Vecima Networks Inc.
REMOTE INTERFACE
The Remote Interface connector is a dual RJ45. The upper socket is used for the Ethernet interface with the lower socket used
for RS232 or RS485. The pin-out for the matching RJ45 plug is shown in the following table and diagram:
D
IAGRAM 4.1C : RJ45 PLUG CONNECTIONS
TABLE 4.1B : RS232 PIN-OUT
Terminal Upconverter
RJ45 Pin Signal Direction Signal RJ45 Pin
1 CTS
←
CTS 1
2 DSR
←
DSR 2
3 RXD
←
TXD 3
4 RXD/GND — RXD/GND 4
5 TXD/GND — TXD/GND 5
6 TXD
→
RXD 6
7 DTR
→
DTR 7
8 RTS
→
RTS 8
( Note: The above pin-out allows a straight through RJ45 cable to be used for connection between the
terminal and the MA4003 chassis. It is also possible to use an RJ45 - DB25 adapter to connect to a PC or
similar RS232 standard serial port.
TABLE 4.1C: RS485 PIN-OUT
Terminal Upconverter
RJ45 Pin Signal Direction Signal RJ45 Pin
1 NC
NC 1
2 NC NC 2
3 A
↔
A 3
4 GND — GND 4
5 GND — GND 5
6 B
↔
B 6
7 NC NC 7
8 NC NC 8
( Note: The above pin-out allows connection to an RS485 communications bus. If desired, an RS485 -
RS232 converter and an RJ45 - DB25 adapter can be used to connect to a PC or similar RS232 serial port.