User's Manual

ma4367_ml_03_sd Approved: B.G. 21
Vecima Networks Inc.
48V - - -
RS232/RS485
MADE IN
CANADA
36-60VDC, 9A MAX.
ALARM
10MHz
REF IN
REMOTE
INTERFACE
FUSE 10A
60VDC
DC INPUT
The DC input accepts input voltages from 36 to 60 VDC. An indicating fuse is included which exposes a marker if the fuse is
blown. If the fuse requires replacement, ensure the voltage and current rating is correct. The fuse type is a 10 Amp, 125VDC
indicating telecom-style fuse. Suggested part numbers are Bussman GMT-10 or Littlefuse 0481010. The fuse mounts with the
indicator to the right. The DC power switch may be used for turning the power on and off to the entire chassis.
ALARM
This connector is used for an external alarm monitor. It is an 8-pin miniature circular connector. The indicated pins are
connected to a dry-contact relay that is active when an alarm is present in the chassis. See Table 4.1A and Diagram 4.1B for
the connector pin descriptions.
DIAGRAM 4.1B : ALARM SOCKET CONNECTIONS
T
ABLE4.1A : ALARM SOCKET PINOUT
Pin Number Function
5 Common
6 Normally closed
7 Normally open
1, 2, 3, 4, 8 Not connected