OUTPUT ENABLE/DISABLE
When this mode is selected, the display will read: Output Enabled
or
Output Disabled
Pressing the Up or Down buttons will toggle the display between Enabled and Disabled. When enabled, the RF output from the MA4070C
Power Amplifier is enabled. When disabled, the RF output from the MA4070C Power Amplifier is disabled.
TEMP
When this mode is selected, the screen indicates the internal temperature of the amplifier.
FORWARD AND REVERSE ALARM THRESHOLD SETTING
The IF and RF alarm threshold can be configured by the user via remote control.
Default settings are as follows: ForwardHigh +41 dB, alarm function disabled
ForwardLow +20 dB, alarm function disabled
ReverseHigh +40 dBm, alarm function disabled
The alarms can be independently enabled or disabled via remote control. Refer to Section 6.5, Detailed Command
Descriptions and System Responses for instructions on how to adjust these settings.