User's Manual
WaveCom Electronics Inc
MA4061/MA4070 Manual; MAN1L2301 Rev02 (Oct 2001)
Approved: R. L.
36
OE
- Enable Output
Description: Turns on the Output from the specified module.
Parameters: None
Example: *999<sp>A<sp>OE<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
OD - Disable Output
Description: Turns off the Output from the specified module.
Parameters: None
Example: *999<sp>A<sp>OD<sp>CRC<cr>
Response:
OK or MOD or ERR or CRC
LE - Enable Local Control
Description: Enables local control of the MA4001B chassis. The module address must indicate a valid module even
though the command does not change any module settings.
Parameters: None
Example: *999<sp>A<sp>LE<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
LD
- Disable Local Control
Description: Disables local control of the MA4001B chassis. The module address must indicate a valid module
even though the command does not change any module settings.
Parameters: None
Example:
*999<sp>A<sp>LD<sp>CRC<cr>
Response: OK or MOD or ERR or CRC