SC - Status Configuration Request
Description: The Status Configuration Request command returns the active configuration, including error codes and
alarm status for the addressed module. It also returns the current status of the power supply module.
The detailed contents of the reply are shown in the response section.
Parameters: None
Example: *999<sp>A<sp>SC<sp>CRC<cr>
Response: OK or ERR or CRC or MOD
If the response is OK, then the following parameters will also be returned in space delimited format in the
order shown below. (Note: X may be replaced by any valid character. All other characters will be as shown).
Error codes are the last two digits reported on the status code line. Refer to Section 6.0, Error Codes (pp 27
to 29) for more details.
T
TT
T
ABLE
ABLEABLE
ABLE7.5.2
7.5.27.5.2
7.5.2B
B B
B : R
: R: R
: RESPONSE
ESPONSE ESPONSE
ESPONSE P
PP
PARAMETERS FOR
ARAMETERS FOR ARAMETERS FOR
ARAMETERS FOR S
SS
STATUS
TATUS TATUS
TATUS C
CC
CONFIGURATION
ONFIGURATION ONFIGURATION
ONFIGURATION R
RR
REQUEST
EQUESTEQUEST
EQUEST
Parameter (Units) Format Example
MA4070 Status Code XXXX 0101
MA4070 RF Power (dBm) XXX.X 31.5
MA4070 RF Reverse Power (dBm) XX.X < 20
FPHS – Forward Power High Set
Description: Sets the Forward Power High for the specified module. When the Forward Power High is enabled, and
the RF Power is above the threshold limit, a non-critical alarm will be triggered.
Parameters: Desired RF Thresholds in dBm, in the form XX.X. The decimal point and trailing characters are
required. The trailing character can range between 0.0 and 0.9
Example: *999<sp>B<sp>FPHS<sp>38.0<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
FPHE – Enable Forward Power High
Description: Enables the Forward Power High for the specified module. When the Forward Power High is enabled,
and the RF Power is above the threshold limit, a non-critical alarm will be triggered.
Parameters: None
Example: *999<sp>B<sp>FPHE<sp>CRC<cr>
Response: OK or MOD or ERR or CRC
FPHD – Disable Forward Power High
Description: Disables the Forward Power High for the specified module.
Parameters: None
Example: *999<sp>B<sp>FPHD<sp>CRC<cr>