User's Manual

WaveCom Electronics Inc
MA4061/MA4070 Manual; MAN1L2301 Rev03 (Mar 2002)
Approved: R. L.
32
MA4061B Command Codes
FL = Load Frequency IAS = Set IF AGC Threshold
AI = Set IF Attenuation IAE = Enable IF AGC Threshold
AR = Set RF Attenuation IAD = Disable IF AGC Threshold
OE = Enable Output RTS = Set RF Threshold
OD = Disable Output RTD = Disable RF Threshold
ITS = Set IF Threshold RTE = Enable RF Threshold
ITD = Disable IF Threshold SU = Unit Status Request
ITE = Enable IF Threshold LE = Enable Local Control
LD = Disable Local Control
MA4070B Command Codes
OE = Enable Output FPHS = Forward Power High Set
OD = Disable Output FPHE = Forward Power Hi Enable
SU = Unit Status Request FPHD = Forward Power High Disable
SC = Configuration Status Request FPLS = Forward Power Low Set
LE = Enable Local Control FPLE = Forward Power Low Enable
LD = Disable Local Control FPLD = Forward Power Low Disable
RPS = Reverse Power Threshold Set
RPE = Reverse Power Threshold Enable
RPE = Reverse Power Threshold Disable
CRC = CRC-16 checksum (3 characters)
The checksum is preferred, but not required. If the checksum is used, the first character is an ASCII “V” followed by
the low and high bytes respectively of the computed CRC 16 checksum (the checksum characters are not
necessarily ASCII). The checksum is to be computed on all characters after the initial <start> character up to, and
including, the first “V” character in the CRC section. If the checksum is not used, the 3 characters should be ASCII
“NNN” (they must be uppercase).
PARM is one or more characters, and is command specific.