OUTPUT ENABLE/DISABLE
When this mode is selected, the display will read: Output Enabled
or
Output Disabled
Pressing the Up or Down buttons will toggle the display between Enabled and Disabled. When enabled, the
RF output from the MA4070 Power Amplifier is enabled. When disabled, the RF output from the MA4070
Power Amplifier is disabled.
An RF output is only present when there is a valid IF input configured as described in the
previous sections. This means that at the time of shipping, the output is disabled until a
valid input is applied.
FORWARD AND REVERSE ALARM THRESHOLD SETTING
The IF and RF alarm threshold can be configured by the user via remote control.
Default settings are as follows: ForwardHigh +41 dB, alarm function enabled
ForwardLow +20 dB, alarm function enabled
ReverseHigh +40 dBm, alarm function enabled
The alarms can be independently enabled or disabled via remote control. Refer to Section 7.5, Detailed
Command Descriptions and System Responses (pp 34 to 40) for instructions on how to adjust these settings.
3.2.3 MA4010B Power/Control Module Modes
ADDRESS
When this mode is selected, the display will read:
Address XXX
The displayed address is the currently selected MA4001B chassis Address. A different
address can be selected by pressing the Up or Down buttons. The MA4001B chassis has
an address from 001 - 999. The address is only used for remote control and monitoring
purposes. The factory default address is 999.
RS232/RS485 SELECT
When this mode is selected, the display will read: RS232 Selected
or
RS485 Selected
Pressing the Up or Down buttons will toggle the display between RS232 and RS485.
The Remote Interface Connector Pinout will change depending upon the Interface Type
selected. Please refer to Section 4.1, Power/Control Module Rear Panel Connection (pp
19, 20) for details.