Specifications

LMS4000 Technical Specifications
Environmental Specifications
Operating Temperature -40º C to 50º C plus solar loading
Storage Temperature -40º C to 70º C
Operating Humidity 0% to 95% RH (non-condensing @ 50C)
Standards Designed for outdoor unsheltered conditions,
Compliant with ETSI-300-019-1-4, Class 4.1 with extended temp. range
(similar to NEMA-4)
Wind Loading Up to 112 mph (180 kph)
maintains alignment to better than 56 mph (90 kph)
Ice Loading Better than 1.25” (32 mm)
Mounting Interface Mounts to any secure pole from 1” to 3.5” (2.5 cm to 9 cm) via 2 gear clamps
Orientation Mounts horizontally or vertically.
Approvals
Radio Transmitter FCC Class A, CFR 47 Part 15. FCC ID: OOX-EUM3006
Safety UL, CSA
V1.0 – Nov. 2004