Specifications

LMS4000 Technical Specifications
Power over Ethernet (PoE)
The EUM3006 is powered by standard 48 VDC Power over Ethernet (802.3af Mode B compatible). Since the antenna is
integrated, there is no need for an RF cable. With PoE, there is no need for a separate power and Ethernet cable. So the
EUM3006 has only one standard flexible cable, making installation simpler.
Using 48 VDC power allows the EUM3006 to have up to 100 m of Ethernet cable to the end-user’s PC, which is the
maximum by the Ethernet standard. The PoE injector can be located anywhere along this 100 m of cable. This provides
great flexibility in placing the EUM3006 to get the best RF signal.
Higher RF Power
Taking advantages of changes to the FCC rules, the EUM3006 makes best use of its high-gain antenna to generate a full
36 dBm AVERAGE EIRP out of the antenna. This represents an increase of about 4 dB from the previous generations of
EUMs with approved high gain antenna systems.
Improved RX Sensitivity
Each EUM3006 is tested to ensure that its RX Sensitivity is -89 dBm or better (average received signal). Combined with
the antenna gain of 10 dBi, the EUM3006 can receive signals at -99 dBm.
DHCP Client
The EUM3006 can obtain its IP address, subnet mask and IP gateway information from a DHCP server, reducing the
amount of configuration needed for installation. This also allows the Network Operator to re-assign IP addresses to EUMs
without having to access the EUM itself.
Auto CCU Discovery
The EUM3006 searches the full RF frequency range to locate CCUs. It then selects the CCU with the best RF signal that
allows it to register. With this and DCHP Client enabled (factory defaults), the installer does not need to enter ANY
configuration parameters into the EUM3006 in order to install it.
Automatic Remote Configuration
The EUM3006 will accept parameters from a RADIUS server to set other configurable parameters in the modem. These
parameters include: password, all SNMP parameters, RF Frequency (including enabling auto-discovery), and number of
customers.
Installation Tools
The EUM3006 has two new tools to make installation and alignment easy and error-free.
MDB1000 - This hand-held, battery-powered device displays detailed key signal quality information to allow the
EUM3006 to be located and aligned to the best RF signal possible by a single installer. The MDB1000 can be in
any position near the EUM3006 to provide easy viewing.
SETUP Menu - The EUM3006 supports the local link IP address, 169.254.10.250, on its Ethernet port at all times.
Using the local-link address, any user can use the password “setup” to call up the setup menu that allows any
user to check the RF link quality to help align the EUM3006 and troubleshoot the link. This avoids needing to
know the IP address and password of the modem.