User's Manual Part 2

Appendix E: Access Interface
APCD-LM043-8.0 (DRAFT C) 223
3. At the prompt, type telnet aaa.bbb.ccc.ddd and press Enter. (aaa.bbb.ccc.ddd
is the IP Ethernet address of the CCU or EUM.)
WaveRider Communications, Inc. LMS3000
Password:
4. At the password prompt, type the device password and press Enter.
NOTE: The default password for CCUs and EUMs is carriage return.
60:ff:fe>
You are now connected to the CCU or EUM with a Telnet session, and you may issue
CLI commands to the device at the command prompt.
Serial Port Connection
To Connect to a CCU3000 or EUM3000 Through a Serial Port
1. Connect and RS-232, DB9 male to DB9 female, straight-through cable between the
console ports on the CCU3000 or EUM3000 and the PC.
2. Open a terminal emulation program, such as Tera Term Pro or HyperTerminal.
NOTE: You can download Tera Term Pro from WaveRider Technical
Support.
3. Connect to the device using the port settings shown in Table 45.
Table 45 Serial Port Settings
4. At the password prompt, type the device password and press Enter.
NOTE: The default password for CCUs and EUMs is carriage return.
You are now connected to the CCU or EUM with a Serial Port session, and you may
issue CLI commands to the device at the command prompt.
Bits per second 9600
Data bits 8
Parity None
Stop bits 1
Flow Control None