User's Manual Part 2

Appendix B: Factory Configuration
APCD-LM043-8.0 (DRAFT C) 187
To reset the EUM to factory default
60:ff:fe> fil dir
Directory listing:
BASIC.CFG 1992
SNTP.CFG 156
SA1110.EXE 475764
PORT.CFG 6240
SA1110.BAK 475764
60:ff:fe> fil del basic.cfg
file deleted
60:ff:fe> fil del sntp.cfg
file deleted
60:ff:fe> fil del port.cfg
file deleted
60:ff:fe> reset
rebooting EUM ...
(... Power On Self Test ...)
WaveRider Communications, Inc. LMS3000
Password:
60:ff:fe> port add 137 both
60:ff:fe> port add 138 both
60:ff:fe> port add 139 both
60:ff:fe> port add 445 both
60:ff:fe> port add 1512 both
60:ff:fe>
60:ff:fe> save
Basic Config saved
Port Filter Config saved
sntp cfg file saved
60:ff:fe>
60:ff:fe> port
PORT FILTERS
Port Filter
---------------------------------
445 both
137 both
138 both
139 both
1512 both
----------------------------------
60:03:3a>