User's Manual Part 2

Appendix B: Factory Configuration
APCD-LM043-8.0 (DRAFT C) 185
To reset the CCU to factory default
60:03:3a> fi dir
Directory listing:
SA1110.EXE 475764
BASIC.CFG 1992
PORT.CFG 6240
SNTP.CFG 156
ROUTE.CFG 2896
AUTHDB.CFG 3496
DHCP.CFG 896
SA1110.BAK 475764
60:03:3a> fil del basic.cfg
file deleted
60:03:3a> fil del port.cfg
file deleted
60:03:3a> fil del sntp.cfg
file deleted
60:03:3a> fil del route.cfg
file deleted
60:03:3a> fil del authdb.cfg
file deleted
60:03:3a> fil del dhcp.cfg
file deleted
60:03:3a> reset
rebooting CCU ...
(... Power On Self Test ...)
WaveRider Communications, Inc. LMS3000
Password:
60:03:3a> port add 137 both
60:03:3a> port add 138 both
60:03:3a> port add 139 both
60:03:3a> port add 445 both
60:03:3a> port add 1512 both
60:03:3a>
60:03:3a> save
Basic Config saved
Port Filter Config saved
sntp cfg file saved
Route Config saved
Authorization Database saved
DHCP Server Config saved
60:03:3a>
60:03:3a> port
PORT FILTERS
Port Filter
---------------------------------
445 both
137 both
138 both
139 both
1512 both
----------------------------------
60:03:3a>