User's Manual Part 2

9: Installing the EUM
APCD-LM043-8.0 (DRAFT C) 157
WaveRider Communications, Inc. LMS3000
Password:
60:03:3a> file get 192.168.10.250
Enter password:
file transfer started (press 'qqq' to abort)...
by 2097152 at 183 kbps24 at 201 kbps
file transfer complete
Transfered "/tffs0/null" Okay.
60:03:3a>
The following three tests use the “ping” command to progressively test the data link.
To Test the Data Link from the End-users PC to the EUM
1. Ping the EUM’s IP address from the end-user’s PC, as follows:
Open a DOS window in the end-user’s PC.
At the command prompt, type
ping <aaa.bbb.ccc.ddd>, where
<aaa.bbb.ccc.ddd> is the IP address of the EUM and press
Enter.
2. If there is no response, check the following:
PC IP address settings.
Ethernet crossover cable between the EUM and the end-user’s PC, to ensure
that the pins have not been damaged.
3. If there is a response, but with errors, check the Ethernet crossover cable.
To illustrate data link testing between the PC and the EUM, consider the sample configuration
shown in Figure 60.
Figure 60 Sample Configuration — Testing the Data Link
Ethernet crossover
cable
EUM Antenna
Gateway Router
Internet
Radio
Link
End-user's Premises
End-user's PC
IP Address 172.16.6.1
Net Mask 22
Gateway IP 172.16.4.1
EUM3000
IP Address 172.16.4.2
Net Mask 22
Gateway IP 172.16.4.1
CCU3000
Radio IP Address
172.16.4.1
Net Mask 22