User's Manual Part 1
APCD-LM043-8.0 (DRAFT C) 135
8 Configuring the EUM
This chapter covers the following procedures:
•
Setting the EUM Password on page 135
•
Configuring the EUM RF Parameters on page 136
•
Configuring EUM IP Parameters on page 137
•
Configuring Port Filtering on page 139
•
Configuring SNMP on page 140
•
Configuring the Customer List on page 142
Before you configure the EUM
• Familiarize yourself with the CLI commands, syntax and shortcuts, outlined in
Appendix C on page 189.
Command-line Syntax provides a complete list of the
available EUM commands, some of which are not discussed in this section.
• Connect a PC to the EUM with a cross-over Ethernet cable and open a Telnet
session.
CAUTION: Remember to regularly enter save or commit and
press
Enter, to save your configuration changes to memory. As
well, some parameters will not take effect until you reboot the unit,
specifically the RF frequency, transmit power and IP addressing.
8.1 Setting the EUM Password
To Change the EUM Password
1. Type password and press Enter.
2. At the
Enter Current Password prompt, type the old password.