User's Manual Part 1
124 APCD-LM043-8.0 (DRAFT C)
7: Configuring the CCU
7.8 Configuring SNMP
To fully configure SNMP
• Set the SNMP contact (name of the WISP, for example).
• Set the SNMP system location (physical location of the CCU, for example).
• Add an SNMP read community.
• Add an SNMP write community.
• Add an SNMP trap community.
To Set the SNMP Contact
1. Type snmp contact <contact> and press Enter.
• <contact> is text field, often used for a contact name and phone number, a
URL, or an email address, from 1-80 characters in length.
2. Type
save or commit and press Enter.
To Set the SNMP System Location
1. Type snmp location <location> and press Enter.
• <location> is the location of the CCU, from 1-80 characters in length.
2. Type
save or commit and press Enter.
To Add an SNMP Read Community
1. Type snmp community add <community> read and press Enter.
• <community> is the name of the read community string. The default read
community string is “public”. The read community string can be from 1-31
characters in length, but spaces are not allowed.
2. Type
save or commit and press Enter.
To Add an SNMP Write Community
1. Type snmp community add <community> write and press Enter.
• <community> is the name of the write community string. The default write
community string is “private”. The write community string can be from 1-31
characters in length, but spaces are not allowed.
2. Type
save or commit and press Enter.
To Add an SNMP Trap Server
1. Type snmp trap add <aaa.bbb.ccc.ddd> <community> and press Enter.
• <aaa.bbb.ccc.ddd> is the IP address of the trap server
• <community> is the name of the community on the trap server, from 1-63
characters in length.
2. Type
save or commit and press Enter.
The following example