User's Manual Part 1
7: Configuring the CCU
APCD-LM043-8.0 (DRAFT C) 113
The system displays a message that your password has been successfully changed.
Example:
60:03:3a> password
Enter Current Password: ********
Enter New Password: ********
Verify password: ********
Saving new password
Password Changed
60:03:3a>
CAUTION: Remember to record the password. Unlocking the
CCU can only be performed by contacting WaveRider Technical
Support.
7.3 Configuring the CCU RF Parameters
To Set the CCU Operating Frequency
1. Type radio frequency <frequency> and press Enter.
• <frequency> is the CCU operating frequency in tenths of a MHz. For example,
917.0 MHz is entered as
9170.
2. Type
save or commit and press Enter.
3. Before the new radio frequency will take effect, you must reboot the CCU by typing
reset and pressing Enter.
To Set the CCU Power Level
1. Type radio rf <power level> and press Enter. <power level> is the CCU
transmit power level, either:
• the desired power level, in dBm, any integer value in the range 15 - 26
inclusive,
•
high (+26 dBm), or
•
low (+15 dBm).
For example,
radio rf 22 will set the RF output power to +22 dBm.
NOTE: Use the HIGH power level unless your site has unique
requirements for which a numerically set power level, or the LOW
power level, is more appropriate. For example, the capability to
numerically set the power level may be useful in high-density
environments, where site-to-site interference is a problem.
2. Type
save or commit and press Enter.
3. Before the new power level will take effect, you must reboot the CCU by typing
reset
and pressing
Enter.