APCD-LM043-4.0 97
8 Configuring the EUM
This chapter covers the following procedures:
Setting the EUM Password on page 98
Configuring the EUM RF Parameters on page 98
Configuring EUM IP Parameters on page 99
Configuring Port Filtering on page 101
Configuring SNMP on page 102
Configuring the Customer List on page 104
Before you configure the EUM
Familiarize yourself with the CLI commands, syntax and shortcuts, outlined in
Appendix C on page 163. Command-line Syntax provides a complete list of the
available EUM commands, some of which are not discussed in this section.
Connect a PC directly to the EUM console port, or through a Telnet session. See
Command-line Interface on page 76 for console settings.
CAUTION: Remember to regularly enter save or commit and
press Enter, to save your configuration changes to memory. As
well, some parameters will not take effect until you reboot the unit,
specifically the RF frequency, transmit power and IP addressing.
CAUTION: After you have finished making your configuration
changes, remember to disconnect your PC from the EUM console
port
CAUTION: When entering IP addresses in the CCU or EUM,
note that a leading 0’ forces the CCU/EUM operating system to
interpret the entry as octal rather than decimal. For example,
pinging 10.0.2.010 actually pings 10.0.2.8