Datasheet
BX
Chap. 12 | Page 3
PORTABLE/WALLMOUNTED ELECTRIC FAN HEATER
Overview of range
Type BX 2E BX 3E BX 5E BX 5EN BX 5ER BX 9SE BX 9AE BX 9ANE
3)
Power supply V 230V~ 230V~ 400V3N~ 230V3~ 230V~ 400V3~ 400V3~ 230V3~
Output kW 2 3 5 5 5 9 9 9
Output steps kW 0-1-2 0-1.5-3 0-2.5-5 0-2.5-5 0-3.3-5 0-4.5-9 0-4.5-9
2)
0-4.5-9
2)
Current A 4.3 / 8.7 6.5 / 13.0 6.3 / 7.2 10.9 / 12.6 14.5 / 21.7 11.3 / 13.0 6.5 / 13.0 11.3 / 22.6
Sound level
1)
dBA 39 44 47 47 47 53 42/53 44/53
Air ow rate m³/h 190 290 500 500 500 900 700/900 700/900
Motor speed r.p.m 1300 1300 1300 1300 1300 1300 1000/1300 1000/1300
Air temp. rise through heater °C 29 29 28 28 28 28 36/ 28 36/28
Degree of protection IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Weight kg 5.2 5.3 6.5 6.5 6.5 10.5 11.5 11.5
Width mm 275 275 275 275 275 350 350 350
Height mm 320 320 320 320 320 450 450 450
Depth (incl. brackets) mm 320 320 320 320 320 370 370 370
1)
Measured at a distance of 5 metres in front of the unit.
2)
Uniform phase loading, even at half output.
3)
e fan motor is continuously in operation.
Type BX 15E BX 20
3)
BX 30
3)
Power supply V 400V3~ 400V3~ 400V3~
Output kW 15 20 30
Output steps kW 0-7, 5-15
2)
0-10-20 0-10-20-30
Current A 10,8 / 21,7 29,5 43,4
Sound level
1)
dBA 55 50/58 50/58
Air ow rate m³/h 1000 1900/2600 1900/2600
Motor speed r.p.m 1300 1000/1300 1000/1300
Air temp. rise through heater °C 42 31/23 47/34
Degree of protection IPX4 IPX4 IPX4
Weight kg 13,5 26 30
Width mm 350 630 630
Height mm 450 585 585
Depth (incl. brackets) mm 435 595 595
1)
Measured at a distance of 5 metres in front of the unit.
2)
Uniform phase loading, even at half output.
3)
e fan motor is continuously in operation.