Specifications

46 VisualSonics Vevo 2100 Imaging System Operator Manual Rev 1.1
Chapter 6: Vevo 2100 Imaging System workspaces
Area Description
Dynamic range bar. Indicates the dynamic range of the display. When you acquire data, use the
Dynamic Range control on the control panel to change the range.
Physiological data trace panel. Displays your animal's dynamic heart rate, temperature,
respiration rate and blood pressure data. This information comes from the Advanced Physiological
Monitoring Unit that connects to the Vevo Imaging Station.
Physiological data values
. Appears only on a stored image or when you pause the system. Can
display the numeric values of the animal's heart rate, respiration rate, blood pressure and body
temperature.
Cine loop range control
. Appears only on a stored or acquired cine loop. Displays the length of
the cine loop range. The triangular white marker identifies the individual frame number within the
cine loop. You can drag the left and right vertical markers to display only the image frames in that
range.
Physiological live display. Appears in real time during image acquisition and can display the
numeric values of the animal's heart rate, respiration rate, blood pressure and body temperature.
This area also displays the
image data storage capacity progress bar so you can see when you
should start to back up your image data to free up space on the system.
Dynamic control panel feedback.
Displays the changing setting values while you use a control panel control until you stop and
the system redraws the image. Then the system displays the setting value in the Mode
settings panel.
Displays confirmation messages when you store an image.
Left panel
. Displays a unique set of controls and information sections depending on the control
key you press:
Press
Mode Settings
to set the panel to display the Mode settings. This is the default
panel when you open a Mode window.
Press
Measure
to set the panel to display the measurement tools. These tools are not
available when you are acquiring or reviewing images.
Press
Physio Settings
to set the panel to display the options for a) viewing and
manipulating physiological data input from the Advanced Physiological Monitoring Unit and b)
manipulating the Respiration Gating and ECG Trigger controls.
For complete information on how each panel works, see Left panel
workspace (page 47).
Operator details
Displays your institution name if you added it in the Preferences window.
Displays your operator name if you selected it for your session.
Identifies the model number of the transducer that is acquiring imaging data (if you are in an
image acquisition session) or the transducer that acquired the data (if you are in an image