Specifications

The CY/CX Module is a high frequency 50 ohm impedance coaxial matrix with
bandpass of DC to 200 MHz.
The matrix is bidirectional and non-blocking, switching any one input to one
output with coaxial dry reed relays which are rated at 10VA.
Standard input and output connectors are SMA with SMBs optionally available.
The basic module has two separate 8x4 matrices
which can be supplied as either one 8x8 or one 16x4
matrix.
GENERAL SPECIFICATIONS
2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475
CY/CX COAXIAL MATRIX
VXI C-SIZE SWITCH MODULE
REED RELAY SPECIFICATIONS
Member of the VXI Plug and Play Alliance..
WARRANTY
CYTEC Corp. warrants that all products are free from de-
fects in workmanship and materials for a period of 5 years.
Reed relays are guaranteed for 100 million operations when
used within their published specifications.
FOR TECHNICAL ASSISTANCE CONTACT 1-800-346-3117 or WWW.CYTEC-ATE.COM
MATRIX CONFIGURATIONS
Power +5 Volts less than 1.2 Amp
+12 Volts 20 mA per energized relay
BULLETIN
CY/CX
CY/CX-2(8x4) - This has two individual 8x4 matrices
as shown in Fig. 1. Each matrix has a bandpass from
DC to 200 MHz (-3dB) with crosstalk of -40dB at 100
MHz.
CY/CX-8x8 - The two 8x4 matrices are interconnected
by isolation relays shown in Fig. 1 to form an 8x8 ma-
trix. The relays also serve to reduce stub length and
maintain bandpass from DC to 170 MHz with crosstalk
of -40dB at 100 MHz.
CY/CX-16x4 - The two 8x4 matrices are interconnected
by additional isolation relays to form a 16x4 matrix. The
relays also serve to reduce stub length and maintain
bandpass from DC to 170 MHz with crosstalk of -40dB
at 100 MHz.
Type S
Contact Rating 10VA
Maximum Switching Voltage 200V
Maximum Switching Current 0.5A
Breakdown Voltage 400V
Operate Time, less than 1ms
DC Isolation - ohm 10
12
Capacitance across reeds 0.1pF
Isolation
Relays