Specifications

The CY Series are low cost C-Size VXI Bus Switch Modules that utilize both Message and Regis-
ter based operation. Available modules include Multiplexers, Matrices, Microwave Switches,
Individual Form A and Form C Relays, Driver Modules, 50 Ohm Coaxial, Solid State and ECL
Matrices.
FULL FIVE YEAR WARRANTY
STATUS of individual relays monitored at the relay
drives.
HIGH RELIABILITY Type S Standard and Type M Mer-
cury Wetted Reed Relays with a guaranteed life of
100 million operations.
LOW THERMAL Relays with offsets less than 1 Fvolt.
MICROWAVE Switches with a Bandpass of DC to 18
GHz; 26 GHz optionally available.
HIGH FREQUENCY 50 ohm impedance 8x8 Coaxial
Matrix with 200 MHz bandpass.
HIGH POWER Switch Modules with 32 Form C Arma-
ture Relays with 150 W or 2000 VA rating.
MULTIPLEXERS with up to 128 switch points.
HIGH DENSITY BIDIRECTIONAL MATRICES up to
16x8 or 62x2 configurations.
"K" MODULES with 64 individual Form A or Form C
relays.
SOLID STATE 48x48 Matrices.
ECL 16x16 Differential Pair Matrix.
BUFFER Amplifier Modules with unity gain for im-
pedance matching.
DIFFERENTIAL INSTRUMENTATION Amplifiers with
preset gains.
DRIVER MODULES with individual current sourcing
or sinking drives.
SOFTWARE
GENERAL SPECIFICATIONS
2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475
CY SERIES
VXI C-SIZE SWITCH MODULES
BULLETIN
CY/10
CYTEC Corp. warrants that all products are free from de-
fects in workmanship and materials for a period of 5 years.
Reed relays are guaranteed for 100 million operations when
used within their published specifications. However, Micro-
wave switches are warranted for 1 year.
WARRANTY
Member of the VXI Plug and Play Alliance..
FEATURES INCLUDE:
VXI Revision 1.4
Logical Address Per DIP Switch Setting
Radiated Emissions Per VXI Specification
Conducted Emissions Per VXI Specification
ENVIRONMENTAL
Operating Temperature 0º to 55ºC
Storage Temperature -25º to 80ºC
Humidity Less than 95% RH no
condensation to 30ºC
Cooling <10ºC rise w/air flow 1.5
L/sec & dP = 0.04 mm H
2
O
Drivers and/or sample programs are available in the most
common programming languages. Please consult our ex-
pert Sales Engineers.
FOR TECHNICAL ASSISTANCE CONTACT 1-800-346-3117 or WWW.CYTEC-ATE.COM