The HXV Series of Computer Controlled Switching Systems are used in High Voltage and HIPOT
applications. They consist of pre-wired Mainframes and Expansion Chassis which hold selected
Switch Modules needed to furnish the required Matrix or Multiplexer configuration.
HXV SERIESHXV SERIES
HXV SERIESHXV SERIES
HXV SERIES
HIGH VHIGH V
HIGH VHIGH V
HIGH V
OLOL
OLOL
OL
TT
TT
T
AA
AA
A
GE / HIPOGE / HIPO
GE / HIPOGE / HIPO
GE / HIPO
T SWITT SWIT
T SWITT SWIT
T SWIT
CHING SYSTEMSCHING SYSTEMS
CHING SYSTEMSCHING SYSTEMS
CHING SYSTEMS
HXV/32 Mainframe with PushButton Manual Control
2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475
LED DISPLALED DISPLA
LED DISPLALED DISPLA
LED DISPLA
YSYS
YSYS
YS
MANUAL CONTROL OPTIONSMANUAL CONTROL OPTIONS
MANUAL CONTROL OPTIONSMANUAL CONTROL OPTIONS
MANUAL CONTROL OPTIONS
CONTROL MODULESCONTROL MODULES
CONTROL MODULESCONTROL MODULES
CONTROL MODULES
IFIF
IFIF
IF
-5 IEEE488/RS232-5 IEEE488/RS232
-5 IEEE488/RS232-5 IEEE488/RS232
-5 IEEE488/RS232
HXV/32
Mainframes have relay status LED Displays built into
the front panels.
HXV/96 and HXV/128 Mainframes and Expansion Chassis
require one CL8 Display Module to drive each switch module.
CL8 LEDs are visible at the front panel. These display mod-
ules must be purchased in addition to the switch modules.
Hot switches up to 3500 volts or 3 amps, carries 5000
volts and 5 amps.
Computer Control from IEEE488 and RS232; Ethernet
LAN or USB are optional.
Front Panel Display of Switchpoint Status with Sta-
tus Feedback to the controlling computer.
Manual Controls optionally available.
CHASSISCHASSIS
CHASSISCHASSIS
CHASSIS
All HXV Chassis are standard 19" rack mounting
width and 15.6" deep. The following chassis are
available:
HXV/32 Mainframe -- Holds up to four HXV Switch Modules.
HXV/96 Mainframe -- Holds up to 12 HXV Switch Modules.
HXV/128 Mainframe -- Holds up to 16 HXV Switch Modules
HXV/96-E and HXV/128-E Expansion Chassis -- Used for
building larger systems. Up to 16 Expansion Chassis can be
controlled from one MESA Control Chassis shown in the MESA
Bulletin.
Chassis Heights:
HXV/32 = 5.25" HXV/96 = 7" HXV/128 = 10.5"
SWITCH MODULESSWITCH MODULES
SWITCH MODULESSWITCH MODULES
SWITCH MODULES
HXV/8x1-A -- Built with eight Form A (SPST) Normally Open
Relays arranged as an 8x1 multiplexer.
HXV/8x1-B -- Has eight Form B (SPDT) Normally Closed Re-
lays.
HXV/8-KA -- Provides eight individual Form A Relays.
HXV/8-KB -- Eight individual Form B Relays.
HXV/4x2 -- Has eight Form A Relays arranged as a 4x2 matrix.
RELARELA
RELARELA
RELA
Y SPECIFICAY SPECIFICA
Y SPECIFICAY SPECIFICA
Y SPECIFICA
TIONSTIONS
TIONSTIONS
TIONS
BULLETIN
HXV-4
•
•
•
•
Pushbutton Manual Controls are optionally available for the
HXV/32 Mainframes. (Specify PB/32). Optional Keypad LCD
Display Manual Controls are offered for the HXV/96 and HXV/
128 Mainframes. (Specify MC-2).
HXV-1
WARRANTYWARRANTY
WARRANTYWARRANTY
WARRANTY
CYTEC Corp. warrants that all products are free from defects
in workmanship and materials for a period of five years. Reed
relays are guaranteed for 100 million operations when used
within their published specifications.
CONTACT 1-800-346-3117 or WWW.CYTEC-ATE.COM FOR TECHNICAL ASSISTANCE
Contact Rating 200 Watts
Switch Voltage 3500 Volts
Switch Current 3.0 Amps
Carry Current 5.0 Amps
Breakdown Voltage 5000 Volts RMS
Operating Time 3.0 msec
Life Expectancy 100 million operations mechanical
SOFTWARESOFTWARE
SOFTWARESOFTWARE
SOFTWARE
Example/Driver programs are available free of charge, written
in most common application languages, including LabView,
LabWindows, Visual Basic and HP Vee.
CONNECTOR OPTIONS:CONNECTOR OPTIONS:
CONNECTOR OPTIONS:CONNECTOR OPTIONS:
CONNECTOR OPTIONS:
SHV - Similar to BNCs. Highest safety.
BP - Banana Plug & Binding Post Type. Lowest Cost.
This Module has both the IEEE488 (Talk/Listen) and the RS232
features detailed in Applications Bulletin AP-5.
IFIF
IFIF
IF
-6 LAN INTERF-6 LAN INTERF
-6 LAN INTERF-6 LAN INTERF
-6 LAN INTERF
AA
AA
A
CECE
CECE
CE
This Module uses TCP/IP to allow control from a Local Area
Network as detailed in Applications Bulletin AP-5.
IFIF
IFIF
IF
-7 EXTERNAL USB/RS232 INTERF-7 EXTERNAL USB/RS232 INTERF
-7 EXTERNAL USB/RS232 INTERF-7 EXTERNAL USB/RS232 INTERF
-7 EXTERNAL USB/RS232 INTERF
AA
AA
A
CECE
CECE
CE
This external cable plugs into a USB port on the controlling
computer at one end and the Cytec Mainframe's RS232 Port
on the other. Allows control via USB at up to 19,200 bps.