Specifications
CONTCONT
CONTCONT
CONT
AA
AA
A
CT 1-800-346-3117, SALES@CYTECCT 1-800-346-3117, SALES@CYTEC
CT 1-800-346-3117, SALES@CYTECCT 1-800-346-3117, SALES@CYTEC
CT 1-800-346-3117, SALES@CYTEC
--
--
-
AA
AA
A
TETE
TETE
TE
.COM OR WWW.COM OR WWW
.COM OR WWW.COM OR WWW
.COM OR WWW
.CYTEC.CYTEC
.CYTEC.CYTEC
.CYTEC
--
--
-
AA
AA
A
TETE
TETE
TE
.COM.COM
.COM.COM
.COM
FOR TECHNICAL ASSISTFOR TECHNICAL ASSIST
FOR TECHNICAL ASSISTFOR TECHNICAL ASSIST
FOR TECHNICAL ASSIST
ANCE AND A COMPLETE CAANCE AND A COMPLETE CA
ANCE AND A COMPLETE CAANCE AND A COMPLETE CA
ANCE AND A COMPLETE CA
TT
TT
T
ALAL
ALAL
AL
OG WITH PRICING!OG WITH PRICING!
OG WITH PRICING!OG WITH PRICING!
OG WITH PRICING!
WW
WW
W
ARRANTYARRANTY
ARRANTYARRANTY
ARRANTY
CYTEC Corp. warrants that all products are free from defects in Material or Workmanship for a period of 5 years and that all
switches are guaranteed for their rated operations.
HXC Series High Current Switching Systems handle up to 150 Amps!
Cytec is proud to introduce a complete line of High Current
Systems. These systems are capable of switching or break-
ing up to 150 amps AC or DC and may be wired into almost
any desired configuration. Relays available for 40 amps, 60
amps or 150 amp applications. Chassis available to drive
from 16 to 128 relays. Call or e-mail for configuration assis-
tance, pricing and availability.
Network Test Access Switches and Power Over Ethernet Test Switches
RJV and RJG Series of Ethernet Test Access Switches
Failsafe and redundancy switches
Specs:
Max Switched Current 40 A 60 A 150 A
Max Switched Voltage 277 VAC, 30 VDC 277 VAC, 400 VDC 277 VAC, 400 VDC
Short term carry current 60 amps, 10 mins. 120 Amps, 15 mins. 300 Amps, 10 mins.
Breakdown voltage 2000 Volts peak 2500 Volts peak 2,500 Volts peak
Mechanical life (operations) 10,000,000 200,000 100,000
Electrical life at max load 100,000 3,000 3,000
Switch time 20 ms 50 ms 50 ms
The RJG Series of Ethernet Switches is designed to handle copper
1000BaseT Gigabit Ethernet signals. They switch all 8 wires of Cat5 or
Cat6 wiring in 1x12 increments for multiplexers or 6x3 matrix incre-
ments.
Allows test access to network segments from your desktop, your home,
or across the planet and reduces the number of analyzers needed.
Both systems use mechanical relays allowing Power Over Ethernet to
be switched.
The RJV Series is cost effective for 10 and 100BaseT systems switch-
ing 2 pairs on CAT5 RJ45 connectors. Modules available as four 1x2's
in latching or non-latching, 12x1 multiplexers or 6x4 matrices. Up to 12
modules per chassis. Many configurations possible.
Primary Server, Hub
Router or Equipment.
Secondary Server, Hub,
Router or Equipment.
Failsafe
Switch
Equipment needing back-up
or failsafe protection
Cytec's Failsafe Switch Systems may be used to provide Network Protection, redundant system switch over for Data Communications or
Power, and even a means to switch to your equipment's backup system when needed. Our passive systems act like a piece of cable so
they can replace messy patch panels, and they permit reconfiguration of systems without ever leaving your desk.
Systems Available for:
Copper Ethernet -- Coax, 10 Base-T, 100 Base-TX, 1000 Base-T.
Fiber -- Multimode or Singlemode.
WAN and Telco -- POTS to T3 copper, OC1 to OC12 Fiber, DSL.
Coaxial and Cable -- DC to 40 GHz, Microwave or Cell.
Serial Data -- RS232, 422, 485, 530, ECL, LVDS, USB, Infiniband.
Video -- Virtually any and all types.
Power -- DC or AC, up to 5000 Volts and 150 amps.
New JX Series High Current Switch Module handles up to 30 Amps!
The new JX8/KP-A and JX8/KP-C Switch Modules handle up to 30 amps of AC at 280 Volts or 20 amps of DC at 28 Volts. Rated to
100,000 operations at full load. This module fits into any existing JX system but does require two open slots per module.
Call or e-mail for price and availability.