SWITCHING SYSTEMS FOR AUTOMATIC TEST, DATA ACQUISITION, COMMUNICATIONS AND CONTROLS AUTOMATED TEST AND DATA ACQUISITION COMMUNICATIONS COMPUTER CONTROLLED MULTIPLEXERS MICROWAVE AND RF NETWORK AND INTERNET MATRIX DISCRETE RELAYS GPIB, IEEE488, RS232, RS422, ETHERNET, LAN, UNIVERSAL SERIAL BUS, PARALLEL TTL FIBER OPTICS VIDEO HIGH VOLTAGE OR CURRENT PLUG-IN PC MODULES VXI, VME, COMPACT PCI BUS SWITCH MODULES FOR TECHNICAL ASSISTANCE CONTACT 1-800-346-3117 www.cytec-ate.com or sales@cytec-ate.
October 2005 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 NEW PRODUCT NEWS CYTEC Corp.
New JX Series High Current Switch Module handles up to 30 Amps! The new JX8/KP-A and JX8/KP-C Switch Modules handle up to 30 amps of AC at 280 Volts or 20 amps of DC at 28 Volts. Rated to 100,000 operations at full load. This module fits into any existing JX system but does require two open slots per module. Call or e-mail for price and availability. HXC Series High Current Switching Systems handle up to 150 Amps! Cytec is proud to introduce a complete line of High Current Systems.
JULY 2002 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 NEW PRODUCT NEWS CYTEC Corp., supplier of the most comprehensive range of Switching Systems, continues to expand its product line by offering the following New Products: NEW FIBER OPTIC SYSTEMS FO SERIES OF PASSIVE FIBER SWITCHING SYSTEMS CYTEC's New FO Series of Fiber Optic Switches use electro mechanical optical relays to form 1xN multiplexers or NxM matrices.
NEW JX32/L2 SWITCH MODULE NEW VME/16X16 RF MATRIX This module has 32 two pole relays as shown in the figure below with signal inputs wired to two 34 pin header connectors. The two 16x1 muxes can be jumpered together to form one 32x1 mux. The outputs are available on a 10 pin header connector or can be jumpered to the card edge connector which plugs into the backplane. It is available with Type A relays only. The relay specs are listed at the bottom of this page.
JULY 2003 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 NEW PRODUCT NEWS CYTEC Corp., Manufacturer of the most comprehensive range of Switching Systems, continues to expand its product line and is now offering the following New Products: NEW TX SERIES 128X128 COAXIAL 50 or 75 OHM SWITCH MATRIX The TX/128x128 Series furnishes both nonblocking and full fan-out solid state switching of 50 or 75 ohm coaxial signals up to 140 MHz.
DX SERIES 64x64 HIGH SPEED DIGITAL SIGNAL SWITCH MATRIX The DX Series Digital 64x64 Matrix switches singleended or differential signals up to 2.0 Gbps. Available for ECL, PECL, LVPECL, LVDS, CML, HDTV or many other digital signal types. Input and output transition boards supply level translations, signal conversion or alternate connector options. SYSTEM FEATURES: • Available in incremental matrix sizes from 16x16 to 64x64. • Matched path lengths for low skew.
BULLETIN MESA-6 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 MESA SERIES MATRIX EXPANSION SYSTEMS The MESA Series Controllers make it possible to control multiple CYTEC switch chassis from one Control Module. It can be utilized to build large Matrix or Multiplexer configurations or simply run multiple different types of chassis. The MESA also saves money on large systems since each chassis does not need a separate control module and often do not need power supplies.
MESA CONTROL UNITS There are three basic models of the MESA Control Unit: the MESA 4, the MESA 16 and the MESA 32. They contain Power Supplies and an Expansion Motherboard. The Control Module and Expansion Interface Modules plug into the Motherboard so that one Control Module can control up to 32 Expansion Chassis. The System shown in Fig. 1 has a MESA 16 Control Unit and four Expansion Chassis arranged and addressed as a 32x16 Matrix.
CM-5 IEEE488/RS232 CM-6 LAN INTERFACE This Module combines both the IEEE488 Talk Listen Control and the RS232 Serial Controls. This is a 10Base-T Ethernet LAN to RS232 interface module which accepts data in TCP/IP format from the Local Area Network and outputs it in RS232 format to the MESA. When used with the RS232 Serial Module, it can control the MESA Control Units with the same Command Structure detailed in the CM-5.
EXPANSION CHASSIS The versatility of the MESA Expansion System is that it enables up to 32 Expansion Chassis of different types to be controlled from one Control Unit. This means that it is possible to build a complete Switching System requiring Matrices, Multiplexers, Group Switches or Individual Relays by selecting the Expansion Chassis and Switch Modules most suitable for the application.
BULLETIN 4600-1 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 4600 SERIES VERY HIGH DENSITY SWITCHING MATRICES CYTEC's new 4600 Series are economical, high density, passive, bidirectional switch matrices. Each chassis holds up to 2048 two pole Type A relays, and a modular design allows great flexibility in creating different switching topologies.
4600 SERIES MAINFRAME Fig. 1 4600 Mainframe Rear View STANDARD MATRIX CONFIGURATIONS 4600 SERIES SWITCH MODULES One of several different possible matrix configurations can be supplied by jumpering the 4600/8(8x2) Switch Modules and/ or the Chassis Motherboard as shown in Fig. 2. The matrix is passive and bidirectional, and any input can be routed to any output without interrupting previously connect I/O paths.
BULLETIN CX/8 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CX SERIES COAXIAL AND RF SWITCHING MATRIX The CX Series of Switching Matrices are available in a variety of single wire coax configurations designed to operate in the range from DC to 700 MHz with many options to minimize price while meeting the desired specifications.
CXB SERIES MODULAR SWITCH MATRIX The CXB Series of Modular Coaxial Switch Matrices provide incremental matrix sizes from 2x4 or 1x8 up to 32x4 or 16x8. 50 ohm signals from DC to 50 MHz can be switched, with isolation of -50 dB at 50 MHz. Up to 16 CXB Switch modules and CL8 Display modules are plugged into the coaxial motherboard to supply the required matrix configurations as shown in Figs. 1 and 2.
CXG SERIES DC to 700 MHz COAXIAL MATRIX CYTEC's CXG Series of coaxial tree switch matrices are available as 4x8 or 8x8 nonblocking configurations in 50 or 75 ohm characteristic impedance. The tree switch topology shown in Fig. 7, provides excellent attenuation and crosstalk specifications from DC to 700 MHz. The use of electromechanical relays make these systems completely bidirectional and capable of hot switching signals up to 24 watts.
CXL SERIES 8x8 BLOCKING MATRIX The CXL/8x8 blocking matrix is a compact and affordable, DC to 700 MHz coaxial 8x8, bidirectional matrix as shown in Fig. 9. The system will allow any input to be connected to any output but requires that the entire switch is reconfigured in order to establish a new path. This may cause a momentary disconnect in previously set paths when a new connection is desired.
BULLETIN CXAR & CT/7 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CXAR AND CT SERIES COAXIAL SWITCHING SYSTEMS The CXAR and CT Series are Computer Controlled Coaxial Switching Systems for High Frequency Signals up to 1.6 GHz. These systems are typically used to configure 1xN multiplexers. Pre-wired Mainframes and Expansion Chassis will accept a variety of control and switch modules to form the desired configuration. FEATURES: • Bandpass from DC to 1.
CXAR CHASSIS The CXAR Chassis are 19" rack mounting units with power supplies and are pre-wired to accept the CXR Series of Switch Modules. The Switch Modules are mounted so that the connectors protrude through the rear panel. The front panel provides LED indication of switch status and optional manual controls. The following Units are available: CXAR/16 and CXAR/32 MAINFRAMES These Chassis control up to 16 or 32 switch points in any configuration. LEDs on the front panel show Switch and Power Status.
CXR-G SWITCH MODULES These modules are designed with Type G relays arranged in a tree configuration as shown in Figs. 4 thru 6 with on board logic which selects the appropriate relays to connect the selected input to the common. Only one input can be switched to one output and in the unenergized state input #0 is connected to the common except the terminated modules which have an open condition. The Modules are available with 50 ohm or 75 ohm characteristic impedance and with SMA, SMB or BNC connectors.
CTC AND CTA A/B SWITCH CHASSIS CTC and CTA Chassis are designed to control either Form C A/B switches (no off position) or Form A A/ B switches (A, B or Off positions). These chassis are commonly used to sub multiplex larger systems or act as stand alone fail safe redundancy systems. Systems are configured according to whether they require one drive per module (Form C versions) or two drives per module (Form A versions).
BULLETIN CXM-2 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CXM SERIES MICROW AVE SWIT CHING SYSTEMS MICROWA SWITCHING CYTEC's CXM Series Microwave Switching Systems are computer controlled units that are designed to switch 50 ohm coaxial microwave signals. These are passive, bidirectional devices. Two basic configurations are available: Nx1 Multiplexers and NxM nonblocking (but not full fanout) Matrices. Bandpass depends on switching topology, but DC to 40 GHz is possible.
CXM MUL TIPLEXERS and MA TRICES MULTIPLEXERS MATRICES Fig. 2 CXM/64 Mainframe configured as two independent 29x1 Multiplexers CXM MA TRICES MATRICES CXM SWIT CH MODULES SWITCH Bidirectional NxM Matrices are assembled by interconnecting the required number of individual microwave switches as shown in Fig. 3. The matrix is nonblocking, but not full fanout. Nonblocking means that any input can be connected to any output without interrupting a previously set path.
DX SERIES 64x64 HIGH SPEED DIGITAL SIGNAL SWITCH MATRIX The DX Series Digital 64x64 Matrix switches singleended or differential signals up to 2.0 Gbps. Available for ECL, PECL, LVPECL, LVDS, CML, HDTV or many other digital signal types. Input and output transition boards supply level translations, signal conversion or alternate connector options. SYSTEM FEATURES: • Available in incremental matrix sizes from 16x16 to 64x64. • Matched path lengths for low skew.
BULLETIN DX-1 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 DX SERIES SOLID ST ATE DIGIT AL SWIT CHING SYSTEMS STA DIGITAL SWITCHING CYTEC's DX Series Switching Systems are based on solid state switch fabric. The Standard DX system is designed to switch TTL, CMOS, LVTTL, IRIG, RS232 and RS422. Input and output buffers are used to convert to RS422 and/or RS232 signal levels. The DX is capable of switching data rates to 80 Mbps NRZ.
SPECIFICA TIONS AND BUFFER OPTIONS SPECIFICATIONS Fig. 2 DX/256x256 Mainframe Rear View with IEEE488 and RS232 Control DX/256x256 SERIES MA TRIX MATRIX INPUT and OUTPUT BUFFERS The DX Series is intended to switch almost any digital stream data stream in a nonblocking (any input to any output without disturbing previously set paths), full fan out (any one input to any or all outputs) configurations. The Basic system is intended to switch TTL or CMOS signal levels.
BULLETIN FX/FO-2 2555 Baird Road, Penfield, New York 14526 (716) 381-4740 FAX (716) 381-0475 FX and FO SERIES FIBER OPTIC SWITCHING SYSTEMS CYTEC's FX Series of Fiberoptic Switching Systems are nonblocking, full fan-out optoelectrical switch matrices available in configurations from 8x8 to 64x64. Different Transmitter/Receiver Module combinations provide for 820, 1310 or 1550 nanometer wavelengths, with data rates to 622 Mb (OC-12/STM-4).
Figure 2 FX/16x16-600-1310 Mainframe Rear View: TRANSCEIVER MODULE OPTIONS FX/100-820-MM and FX/100-1310-MM FX/600-1310 and FX/600-1550 SERIES Includes the FXR-100-820 Receiver and FXT-100-820 Transmitter Modules for 820 nm wavelengths as well as the FXT-100-1310 Transmitter and FXR/100-1310 Receiver Modules for 1310 nm. Eight individual input or output channels are supplied by each Receiver or Transmitter module. Multimode cables at data rates up to 155 Mb/ sec (NRZ) are supported.
FO SERIES PASSIVE FIBER OPTIC SWITCHING SYSTEMS CYTEC's new FO Series Passive Fiberoptic Switching Systems are computer controlled chassis that are designed to switch standard fiberoptic wavelengths of 850 nm, 1310 nm and 1550 nm. Multimode 62.5/125 um switches are available for 850 nm and 1310 nm wavelengths, while Singlemode 9/125 um switches are available for 1310 nm and 1550 nm. Passive, bidirectional Moving Fiberoptic Switches are used that show insertion losses as low as 0.10 dB for Multimode and 0.
Fig. 4 FO/8 Mainframe with two FO/2x1 Switches Installed FO SERIES MULTIPLEXERS LED DISPLAYS Bidirectional Nx1 Multiplexers are assembled from standard FO Chassis by interconnecting Fiberoptic Switch Modules as shown schematically in Fig. 5. The interconnects are fiberoptic cables and are usually wired externally, on the rear panel. Internally wired systems may be ordered as an option. FO/8, FO/16 and FO/32 Chassis are built with individual, discrete front panel LEDs that show switchpoint status.
BULLETIN GX-3 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 GX SERIES GROUP SWIT CHING MA TRICES and MUL TIPLEXERS SWITCHING MATRICES MULTIPLEXERS Standard CYTEC Switch Modules are available that can switch 8, 16 or 32 signal wires simultaneously. These modules can be custom configured as Group Switches to handle large number of signals per switched crosspoint.
GX SERIES CHASSIS The GX Series Chassis are built as either single chassis Mainframes or as Expansion Chassis controlled by one GX Series Control Unit. For larger systems having more than 16 groups, the MESA Control Unit is used to control several GX/16 Control Units. GX MAINFRAMES GX CONTROL UNITS These single chassis Mainframes are built with their own dedicated power supplies, a Control Module, and have front panel status LEDs.
BULLETIN HXV-4 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 HXV SERIES HIGH V OL TAGE / HIPO T SWIT CHING SYSTEMS VOL OLT HIPOT SWITCHING The HXV Series of Computer Controlled Switching Systems are used in High Voltage and HIPOT applications. They consist of pre-wired Mainframes and Expansion Chassis which hold selected Switch Modules needed to furnish the required Matrix or Multiplexer configuration.
HXV CHASSIS The HXV Chassis are 19" rack mounting chassis that are pre-wired to hold the HXV Series of Switch Modules. Mainframe chassis include built-in power supplies. The Switch Modules mount so that the signal I/O connectors protrude through the chassis' rear panel. Power and control connectors are also mounted on the rear panel. The front panel has LEDs that show power ON and switch status. Optional manual controls also mount on the front panel.
BULLETIN J-8 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 Fax (585) 381-0475 JX SERIES MATRIX/MULTIPLEXERS FOR DATA ACQUISITION AND AUTOMATIC TEST This compact and economically priced Series can be used as either Multiplexers, Matrices or Individual Switches. As Multiplexers, they can be used as a single multiplexer to switch a large number of inputs or outputs to one commpon port , or as a dual multiplexer to switch between either of two common ports.
SERIES JX16 SWITCH MODULES The JX16 Switch Modules plug into the JX/256 Mainframe and Expansion Chassis and typically are built with 16 relays and their associated solid state controls, including Status feedback. The Modules are available with high reliability reed relays that have a guaranteed life of 100 million operations and with the option of either Type S - Standard Dry Reed, Type M - Mercury Wetted Reed or Type LT - Low Thermal Reed.
JX16/AB SWITCH MODULES JX16/PROTO-I/O MODULE These Modules typically have 16 relays configured as an 8x2 Matrix so that any of 8 inputs can be switched to either of 2 outputs. Bandpass is better than 20 MHz (-3dB) and Isolation is less than 40 dB at 100 kHz when used in a JX/256 chassis. This module, shown in Fig. 10, plugs into the JX Series backplane and has logic to control 16 TTL Outputs or Relay Driver Outputs and 16 TTL compatible inputs.
CONTROL MODULES Plug in modules can control the JX/256 Mainframe from either TTL Port, Combined IEEE488 BUS / RS232 Serial BUS or 10Base-T Ethernet LAN. The Control Module selects any switch in the Mainframe and Latches or Unlatches the switch in either the Matrix or Multiplexer Mode and can also request the Status of selected switches. In the Matrix Mode, any number of relays can be selected and Latched or Unlatched. In the Multiplex Mode, only one relay is selected and Latched.
BULLETIN LX-6 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 Fax (585) 381-0475 LX SERIES GENERAL PURPOSE SWIT CHING MA TRICES SWITCHING MATRICES FOR A UT OMA TIC TEST ATION AND CONTROL AUT UTOMA OMATIC TEST,, INSTRUMENT INSTRUMENTA The LX Series are high reliability, low cost, versatile Switching Systems. A modular design concept is used. Interchangeable Control Modules, Switch Modules and Display Modules can be assembled into Matrices, Multiplexers or Individual Switch Point configurations.
LXA GENERAL PURPOSE SERIES The LXA Series are 19" rack mounting Mainframes or Expansion Chassis, 3.5" high, with motherboards that hold any of the LX Series of Switch Modules, Latching/Display Modules and a Control Module. LXA/128 MAINFRAME SWITCH MODULES LX8/G2 This chassis is 15.6" deep. It is built with power supplies and motherboards that hold a Control Module, up to 16 LX8 Switch Modules and 16 CL8 Latching/Display Modules. The Signal Motherboard busses the switch modules together (shown in Fig.
LXB MA TRIX SERIES MATRIX The LXB Series units are two pole switch matrices and are available as either Mainframes or Expansion Chassis. They are well suited for use in two wire data communications applications, including T1 and ISDN, where wiring is minimized and performance is optimized. The following matrix configurations are available: Two separate 16x4's in one chassis, one 16x8, one 32x4 or one 64x2. Signals connectors include BNCs, Screw Terminals or Three Pin Headers.
GX GROUP SWITCH LX CONTROL MODULES LX8/G2 Switch Modules can be used in either the GX/8 or GX/16 Group Switch Chassis to switch signals in groups of 16 wires in up to a 16x1 Multiplexer configuration. For more information see the GX Bulletin. The LX Mainframes can be computer controlled via the modules listed below. Each Control Module selects any Switchpoint and Latches, Unlatches and returns Status of that point.
BULLETIN PCB/PCI-4 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 PC-B/PCI SERIES MODULES The PC-B Series Modules plug into PC/AT/XT Compatible ISA Bus slots. The PCI Modules plug into PCI slots. Both are available as either Switch Modules or Driver Modules. The modules can be controlled either by direct hardware port access or by installable Device Drivers. PCI Moduldes come with Plug and Play device drivers.
PC-B/2(8x1) SWITCH MODULE PCI BUS INTERNAL PC MODULES The PC-B/2 (8x1) Switch Module is a general purpose module which can be used in either Matrix or Multiplexer applications. It has 16 two pole relays configured as two separate 8x1 two wire Multiplexers as shown in Fig. 3 which can be jumpered as one 16x1 two wire Multiplexer. COM 0 1 2 3 4 5 6 7 COM 8 9 10 11 12 13 14 15 Fig.
BULLETIN PX-6 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 Fax (585) 381-0475 PX/512 SWITCH MATRIX The PX/512 Series of Switching Matrices are compact and economically priced units using high reliability Reed Relay Modules assembled into pre-wired Mainframes or Expansion Chassis to assemble a 32x16 Matrix, two 32x8 Matrices or a 64x8 Matrix with either single or two pole signal switching. Computer Control can be from IEEE488 BUS, RS232 Serial or 10Base-T LAN.
PX/32 SWITCH MODULES Each switch module has 32 single or two pole relays and includes the logic for Selecting the module, Selecting and Latching the relay and obtaining the Status of the relay. Status is obtained by checking the drive to the relays which verifies that the logic is operating correctly and that the selected relay is energized.
TWO POLE SWITCH MODULES These Modules are available as either 2x16 Matrices or two 2x8 Matrices and with either Type S dry reed relays, Type M mercury wetted reed relays or Type LT low thermal relays. The inputs to the modules can be either BNC receptacles (-N), 20 pin headers (-H) or screw terminals (-S). Both the center conductor and isolated shield of the BNC are switched.
SWITCH SPECIFICATIONS Three types of switches are available, the Type S, Type M and Type LT. Type S Standard is a dry reed switch for most medium range applications. Type M Mercury is a mercury wetted switch for high power or low contact resistance applications. Type LT Low Thermal is a dry reed switch for low level applications with less than 1 microvolt offset.
BULLETIN RJ-4 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 RJ SERIES SWITCHING SYSTEMS FOR COMMUNICATIONS AND AUTOMATED TEST The RJ Series of Computer Controlled Switching Systems are engineered for both analog and digital communication applications. A modular design is used, and interchangeable Control Modules, Switch Modules and Display Modules plug into prewired chassis. This allows systems to be tailored to fit specific applications.
RJM SERIES HIGH PERFORMANCE MATRICES The RJM Series are high Performance, bidirectional, passive Matrices and are designed to switch high speed communication signals, including T1, E1, DSL and 100Base-T Ethernet. High sensitivity Type A Armature Relays and CAT5 RJ45 connectors are used to ensure that high pair-topair isolation, and CAT5 attenuation and crosstalk specifications are met.
RJV SERIES MULTIPLEXERS and MATRICES The RJV Series are high performance, bidirectional, passive Multiplexers or Matrices designed for demanding communication applications such as 100Base-T Network Switching. These units are built with high sensitivity Type A Armature Relays to insure low signal-to-signal crosstalk. Exceptional longitudinal balance and low insertion losses are achieved at high data rates. Connectors are CAT5 RJ45.
RJB SERIES SOLID STATE SWITCH MATRICES The RJB Series are bidirectional, nonblocking, four wire Solid State Matrices and are used to switch the following signal types: TTL level analog or digital (0-5 volts), 10Base-T or Token Ring. Each Mainframe is built with integrated power supplies, a Control Module, either an 8x8 or 16x16 Solid State Switch Module and one of three types of built in Interface Modules. The Interface Modules adapt the solid state switch fabric to the signals that are to be switched.
RJA SERIES HIGH RELIABILITY MATRICES The RJA Series are low cost, high reliability, passive Matrices that are designed for analog voice and digital communication applications. Two, four or six pins on RJ12 Jacks are switched using reed relays. Each mainframe holds power supplies, a Control Module, up to 16 Switch Modules and CL8 Display Modules. CL8 Modules control the switch module and show switch status. RJA/128 MAINFRAMES RJ SWITCH MODULES These are 19" rack mounting chassis, 3.5" high and 12" deep.
CONTROLS The RJ Series Mainframes are computer controlled via: IEEE488 BUS, RS232 Serial, Ethernet LAN, Universal Serial Bus (USB) or TTL Parallel Port. The Control Module selects any Mainframe switch point and is able to Latch, Unlatch and Request Status of the switch in both Matrix and Multiplex Modes. In the Matrix Mode, any number of switches can be closed at the same time. In the Multiplex Mode, only one switch can be closed at a time.
BULLETIN RS-4 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 RS SERIES SWIT CHING SYSTEMS SWITCHING FOR A UT OMA TIC TEST AND COMMUNICA TIONS AUT UTOMA OMATIC COMMUNICATIONS The RS Series of computer controlled switching systems are designed to switch multiwire groups of signals of up to 25 wires.
RS MUL TIPLEXER MULTIPLEXER RSS MA TRIX MATRIX These are passive, relay-based multiplexers switching from 9 to 25 wire signals such as RS232, RS422 or TTL in applications including Modems, Printers or Token Ring. Their Bandpass is DC to 20 MHz. These are built up from the RSS/16x8 Solid State Modules, which in turn are plugged into pre-wired RSS chassis. Each module is an individual 16x8 Matrix, and multiple modules can be interconnected to form larger matrix configurations.
RSM MA TRICES MATRICES RSM Matrices are designed to switch multiwire data communications signals such as RS232, RS422 and Token Ring. RSM Systems can switch 9, 15 or 25 wires and are available with D9, D15 or D25 style connectors. SWIT CH MODULES SWITCH MAINFRAMES Mainframes are 19" rack mounted chassis, 7" (4U) high and 21" deep, with power supplies and pre-wired motherboards that hold Switch Modules, LED Display Modules and Control Modules.
CONTROLS The RS Series of computer controlled Mainframes are available with the following controls: combined IEEE488/RS232 (standard), or optional Parallel Port TTL, Ethernet LAN or USB. The controls select any switch and can Latch, Unlatch and request Status of the switch using either Matrix or Multiplex Modes. In the Matrix Mode, any number of switches can be Latched as required. In the Multiplex Mode, only one switch can be Latched at any time; any previously latched switches are cleared.
BULLETIN VDX-2 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 VDX SERIES VIDEO AND RF SWITCHING SYSTEMS CYTEC's VDX Series of Video and RF Switching Systems are based on a solid state switch fabric and are available in nonblocking, full fan-out configurations of 16x16 and 32x32, with bandpass to 200 MHz. Input and output buffers can be added to the basic switch fabric allowing a broad range of both 75 and 50 ohm impedance signals to be switched.
SPECIFICATIONS AND BUFFER OPTIONS RS-232 Fig. 2 LINK RS-232 UTP VDX/32x32 Mainframe with RS232 and LAN Control and BNC Signal Connections VDX SERIES MATRIX INPUT and OUTPUT BUFFERS The VDX Series is intended to switch small signal levels in a nonblocking (any input to any output), full fan out (any input to any or all outputs) configurations. The heart of the system is a solid state 32x32 switch fabric.
BULLETIN VM-3 2555 Baird Road, Penfield, New York 14526 (716) 381-4740 FAX (716) 381-0475 VM SERIES VME AND VXI SWITCH MODULES The VM Series of Switch Modules are available as either VME size 6U Modules or VXI size B Modules and include Multiplexers, Matrices, Discrete Relays and Coaxial Matrices. FEATURES INCLUDE: • • • • • • • • • VXI Rev. 1.4 Register based operation. Status and Control Registers. Simple BYTE read and write for parallel access to relays. Status readback from relay coils.
VM/8x4 MATRIX SWITCH MODULE VM/24KCP POWER RELAYS This module has two 4x4 two wire matrices with Inputs and Outputs brought out to 16 pin Header connectors as shown in Fig. 3. The two matrices can be combined as one 8x4 matrix. This module has 24 single pole double throw armature type power relays wired out in groups of 8 relays to 25 pin D type connectors shown in Fig. 4. 1 of 3 Circuits 25 Pin D-Type Connector 16 Pin Headers 16 Pin Headers Fig.
BULLETIN VX-5 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 Fax (585) 381-0475 VX SERIES SWITCHING SYSTEMS FOR AUTOMATIC TEST, INSTRUMENTATION AND COMMUNICATIONS The VX Series of low-cost, versatile Switching Systems use a modular concept of Switch Modules, Display Modules and Control Modules which can be assembled into VX/256 Mainframes as Matrices, Multiplexers or Individual Relays. All units have front panel LED displays and Status feedback of selected relays.
VX/256 CHASSIS The VX/256 Chassis consist of Mainframes and Expansion Chassis with pre-wired motherboards which accept 16 of the VX Switch Modules and Display Modules. The motherboards are assembled so that the Switch Module signal connectors are accessible from the chassis back panel and the LEDs are visible through the front panel. The VX/256 Mainframes have power supplies and are pre-wired for a Control Module.
VX GENERAL PURPOSE MODULES VX/G SWITCH MODULES VX/K SWITCH MODULES These modules have the inputs of 16 relays wired to header connectors on the rear edge of the module and the outputs wired to the motherboard as shown in Figs. 5 & 6. Plugged into the bussed motherboard, the modules can be wired in configurations of 16x16, 32x8, 64x4, 128x2 or 256x1. The following types of modules are available: VX16/G1 has 16 single pole relays wired to two 20 pin headers as shown in Fig.
GX GROUP SWITCH CONTROL MODULES VX16/G2 & VX16/G3 Switch Modules can be used in the GX/16 Group Switch Chassis to switch signals in groups of up to 48 wires in up to a 16x1 Multiplexer configuration. For more information see GX Bulletin. The VX Mainframes can be computer controlled via the modules listed below. Each Control Module selects any switchpoint and Latches, Unlatches and returns Status of that point.
SWITCHING SYSTEMS LOW COST SOLUTIONS FROM THE SWITCHING SPECIALISTS. • MATRICES • MULTIPLEXERS • POWER RELAYS • COAXIAL MATRICES • CUSTOM MODULES. Full B Size Assortment of Modules and C Size VXI VME Modules Switch Modules also available Member of the Alliance FOR TECHNICAL ASSISTANCE or a FULL PRODUCT CATALOG, CONTACT 1-800-346-3117 or www.cytec-ate.com or sales@cytec-ate.
BULLETIN CY/10 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY SERIES VXI C-SIZE SWITCH MODULES The CY Series are low cost C-Size VXI Bus Switch Modules that utilize both Message and Register based operation. Available modules include Multiplexers, Matrices, Microwave Switches, Individual Form A and Form C Relays, Driver Modules, 50 Ohm Coaxial, Solid State and ECL Matrices.
CY SERIES RELAY SPECIFICATIONS MICROWAVE RELAYS • Type S - Standard Dry Reed Relays. • Type M - Mercury Wetted Reed Relays. • Type LT - Low Thermal Reed Relays. • Type P - Armature Power Relays. • Type A - Instrumentation Level Signal Armature Relays. Relays have the following guaranteed lifetimes when operated within the specified operating parameters. These CY/G and CY/M Modules are available as individual relays or as multiplexers or wired in a variety of different configurations including matrices.
BULLETIN CY/128 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/128 MULTIPLEXER VXI C-SIZE SWITCH MODULE The CY/128 is a bidirectional reed relay multiplexer and is used in general purpose switching applications. The module is designed with flexibility in mind, and a variety of different configurations are available. This allows the users to choose the configuration which most closely matches their requirements.
BULLETIN CY/64x2 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/64x2 SINGLE POLE MATRIX VXI C-SIZE SWITCH MODULE The CY/64x2 is a bidirectional reed relay matrix and is designed for general purpose switching applications. The module can be configured in a variety of different ways. The users can specify the configuration which most closely matches their requirements. All CYTEC VXI Modules use both Message and Register based operation.
BULLETIN CY/64K 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/64K & CY/64KC VXI C-SIZE INDIVIDUAL RELAY SWITCH MODULES Each of these VXI Switch Modules provides 64 individual switch points. The CY/64K supplies 64 Form A reed relays, while the CY/64KC furnishes 64 Form C general purpose armature relays. Any number or relays may be closed simultaneously and relay status may be read at any time. All CYTEC products utilize both Register and Message based operation.
BULLETIN CY/DRV 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/64DRV RELAY/SOLENOID DRIVER MODULE CY/32KCP FORM C POWER SWITCH MODULE CYTEC's CY/64DRV VXI C-Size Driver Module is built with 64 individually addressable current sourcing or sinking drives and is designed to power external loads such as relays or solenoids. The CY/32KCP has 32 Form C Power Relays that can switch up to 8 A of current and 150 watts DC or 2000 watts AC.
BULLETIN CY/CX 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/CX COAXIAL MATRIX VXI C-SIZE SWITCH MODULE The CY/CX Module is a high frequency 50 ohm impedance coaxial matrix with bandpass of DC to 200 MHz. The matrix is bidirectional and non-blocking, switching any one input to one output with coaxial dry reed relays which are rated at 10VA. Standard input and output connectors are SMA with SMBs optionally available.
BULLETIN CY/8x8 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/8X8 REED RELAY MATRIX VXI C-SIZE GENERAL PURPOSE SWITCH MODULE The CY/8x8 is a general purpose, bidirectional reed relay matrix. It is a true nonblocking matrix, and each input can be connected to one, many or all outputs concurrently. All CYTEC VXI Modules utilize both Message and Register based operation. 34 Pin Header The CY/8x8 supplies two individual 8x4 matrices.
BULLETIN CY/16x8 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/16X8 ARMATURE RELAY MATRIX VXI C-SIZE GENERAL PURPOSE SWITCH MODULE The CY/16x8 is a two pole, bidirectional armature relay matrix that is used to switch instrumentation level signals. It is a true non-blocking unit, and each input can simultaneously be connected to one, many or all outputs. All CYTEC VXI Switch Modules utilize both Message and Register based operation.
BULLETIN CY/MW 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 CY/G AND CY/M C-SIZE VXI MICROWAVE SWITCH MODULES The CY/G and CY/M Series of Microwave Switch Modules have user defined configurations and are used to switch RF Signals. Bandpasses of approximately 1.0, 18 and 26 GHz can be provided, and characteristic impedances of either 50 or 75 ohms are available.
F o r a d d i ti o n a l de tai l s con t act Cyt ec te ch ni ca l sa le s at 1-8 00-346- 3117 or www.c y te c-a t e. co m o r sa l es @ cy te c-a t e.
APPLICATIONS BULLETIN AP-5 2555 Baird Road, Penfield, New York 14526 (585) 381-4740 FAX (585) 381-0475 IEEE488/RS232, AND LAN INTERFACE MODULES The following Control Modules are available: IEEE488/RS232 CONTROL MODULE is a combined Control Module with all the features of the IEEE488 GPIB Bus and the RS232 Serial Module. LAN unit transfers 10Base-T LAN data to the RS232 Module. IEEE488/RS232 COMBINED CONTROLMODULE IEEE488 GPIB FEATURES This module has the following device subsets.
RS232 SERIAL FEATURES The module can be configured as either a Data Terminal Equipment (DTE) or Data Communications Equipment (DCE) and the Baud Rate is software programmable from 110 to 19,200 Baud, stored in nonvolatile memory. This module has the same command structure as the IEEE488 Talk/Listen and has these additional features: E - Echo A - Answerback V - Verbose H - Help P - Program - Echos all received characters back to the source.