Specifications
ControlsControls
ControlsControls
Controls
RJE/RJM Control ModulesRJE/RJM Control Modules
RJE/RJM Control ModulesRJE/RJM Control Modules
RJE/RJM Control Modules
IFIF
IFIF
IF
-5 IEEE488/RS232-5 IEEE488/RS232
-5 IEEE488/RS232-5 IEEE488/RS232
-5 IEEE488/RS232
M/128 Manual ControlsM/128 Manual Controls
M/128 Manual ControlsM/128 Manual Controls
M/128 Manual Controls
RJF/RJG/RJV SERIES ControlsRJF/RJG/RJV SERIES Controls
RJF/RJG/RJV SERIES ControlsRJF/RJG/RJV SERIES Controls
RJF/RJG/RJV SERIES Controls
MC/2 Manual Control - RJV ONLMC/2 Manual Control - RJV ONL
MC/2 Manual Control - RJV ONLMC/2 Manual Control - RJV ONL
MC/2 Manual Control - RJV ONL
YY
YY
Y
Switch SpecificationsSwitch Specifications
Switch SpecificationsSwitch Specifications
Switch Specifications
IFIF
IFIF
IF
-7 Combined USB/RS232-7 Combined USB/RS232
-7 Combined USB/RS232-7 Combined USB/RS232
-7 Combined USB/RS232
IFIF
IFIF
IF
-7 Combined USB/RS232-7 Combined USB/RS232
-7 Combined USB/RS232-7 Combined USB/RS232
-7 Combined USB/RS232
This module combines both the IEEE488 BUS and RS232 fea-
tures detailed in Applications Bulletin AP-5.
This control module is plug-and-play compatible with Universal
Serial Bus and furnishes dual controls via both RS232 and USB,
allowing users to switch to USB control as COM ports become
obsolete on new computers.
IFIF
IFIF
IF
-6 -6
-6 -6
-6
LAN INTERFLAN INTERF
LAN INTERFLAN INTERF
LAN INTERF
AA
AA
A
CECE
CECE
CE
This module allows control via a Local Area Network using TCP/
IP protocols detailed in the AP-5 Bulletin.
This module allows control via a Local Area Network using TCP/
IP protocols detailed in the AP-5 Bulletin.
IFIF
IFIF
IF
-6 -6
-6 -6
-6
LAN INTERFLAN INTERF
LAN INTERFLAN INTERF
LAN INTERF
AA
AA
A
C EC E
C EC E
C E
The RJM Matrices and RJV Multiplexers are built with high
sensitivity Type A Armature relays. pole versions only.
This control module is plug-and-play compatible with Universal
Serial Bus and furnishes dual controls via both RS232 and USB,
allowing users to switch to USB control as COM ports become
obsolete on new computers.
This Manual Control Option has a Keypad and LCD Display on
the front panel so that the operator can select any relay and
verify that the relay has been selected via the display. It is only
available for the RJV Series.
Additional Manual Control OptionsAdditional Manual Control Options
Additional Manual Control OptionsAdditional Manual Control Options
Additional Manual Control Options
The following Manual Control Options are available for ALL
chassis mentioned in this Bulletin. Contact our Technical
Sales Representatives for more details and information.
The RJ Series Mainframes are computer controlled via: IEEE488 BUS, RS232 Serial, Ethernet LAN, Uni-
versal Serial Bus (USB) or TTL Parallel Port. The Control Module selects any Mainframe switch point and
is able to Latch, Unlatch and Request Status of the switch in both Matrix and Multiplex Modes.
In the Matrix Mode, any number of switches can be closed at the same time. In the Multiplex Mode, only
one switch can be closed at a time.
RJ-6
WW
WW
W
ARRANTYARRANTY
ARRANTYARRANTY
ARRANTY
CYTEC Corp. warrants that all products are free from defects in
material or workmanship for a period of five years.
SOFTWSOFTW
SOFTWSOFTW
SOFTW
AREARE
AREARE
ARE
Free drivers and/or sample programs are available for the most
commonly available application programming languages.
CYTEC SWITCYTEC SWIT
CYTEC SWITCYTEC SWIT
CYTEC SWIT
CH MANACH MANA
CH MANACH MANA
CH MANA
GER SOFTWGER SOFTW
GER SOFTWGER SOFTW
GER SOFTW
AREARE
AREARE
ARE
The Cytec Switch Manager provides a GUI inter-
face for controlling matrices and multiplexers via
remote computer. The software includes an in-
tuitive graphical interface, security implementa-
tion, built in test functionality, multiple device control,
switchpoint memory, as well as many other useful features.
You can download the Switch Manager free of charge from
our website.
Available for Windows, Linux, Mac OS, or any other
Java enabled platform
FOR TECHNICAL ASSISTFOR TECHNICAL ASSIST
FOR TECHNICAL ASSISTFOR TECHNICAL ASSIST
FOR TECHNICAL ASSIST
ANCEANCE
ANCEANCE
ANCE
, PLEASE CONT, PLEASE CONT
, PLEASE CONT, PLEASE CONT
, PLEASE CONT
AA
AA
A
CT CYTEC ACT CYTEC A
CT CYTEC ACT CYTEC A
CT CYTEC A
TT
TT
T
800-346-3117 OR VISIT OUR WEBSITE A800-346-3117 OR VISIT OUR WEBSITE A
800-346-3117 OR VISIT OUR WEBSITE A800-346-3117 OR VISIT OUR WEBSITE A
800-346-3117 OR VISIT OUR WEBSITE A
T cytec-ate.comT cytec-ate.com
T cytec-ate.comT cytec-ate.com
T cytec-ate.com
All ChassisAll Chassis
All ChassisAll Chassis
All Chassis
Material:
Mounting Hardware:
Protection:
Gray Anodized extruded or sheet
aluminum with a polycarbonate
front panel overlay.
Rack mount handles are stan-
dard. Flush mount flanges
available at no cost.
Selectable AC input fused at: 2
amps 110 VAC, 1 amp 220 VAC.
Thumbwheels and switches on the front panel select and con-
trol up to 128 relays.
SPECIFICATION TYPE A
Contact Rating VA 30
Switching Voltage DC 110V
Switching Current DC 1.0 A
Carrying Current DC 1.0A
Breakdown Voltage DC 750V
Operate Time msec 3