Specifications
RJ-2
The RJV Series are high performance, bidirectional, passive Multiplexers or Matrices designed
for demanding communication applications such as 100Base-T Network Switching. These units
are built with high sensitivity Type A Armature Relays to insure low signal-to-signal crosstalk.
Exceptional longitudinal balance and low insertion losses are achieved at high data rates. Con-
nectors are CAT5 RJ45. A modularized design is used, and each Mainframe is built with inte-
grated power supplies, a Control Module and a motherboard that holds the RJV Switch Modules.
This results in a great deal of configuration flexibility.
RJV/48 MainframeRJV/48 Mainframe
RJV/48 MainframeRJV/48 Mainframe
RJV/48 Mainframe
This chassis is 5.25" high and accepts up to four RJV Series
Switch Modules. The modules can be used individually, or
bussed together in several different configurations (for ex-
ample, as a 48x1 Mux). Bandpass is 100 MHz at -2dB and
Near End Crosstalk between wire pairs (NEXT) is -42dB at 80
MHz, which exceeds 100Base-TX network specifications.
RJV SERIES - RJV SERIES -
RJV SERIES - RJV SERIES -
RJV SERIES - Matrices & Multiplexers (up to 144 channels)
19" rack mount (483 mm)
16" depth (396 mm)
3.5" (2 RU) height (89 mm)
15 lbs (6.8 Kg) Max
50 Watts max (110/220 selectable)
Dimensions:
Weight:
AC Power:
RJV/144 MainframeRJV/144 Mainframe
RJV/144 MainframeRJV/144 Mainframe
RJV/144 Mainframe
This is a 19" rack mounting chassis, 10.5" high and 16" deep,
designed to hold up to 12 RJV Series Switch Modules. Mod-
ules can be used individually or bussed together in several
configurations. In all configurations, 100Base-TX Bandpass
and NEXT specifications are met.
19" rack mount (483 mm)
16" depth (396 mm)
3.5" (2 RU) height (89 mm)
25 lbs (11.4 Kg) Max
100 Watts max (110/220 selectable)
Dimensions:
Weight:
AC Power:
RJV/144-E Expansion ChassisRJV/144-E Expansion Chassis
RJV/144-E Expansion ChassisRJV/144-E Expansion Chassis
RJV/144-E Expansion Chassis
This is the same as the mainframe above but is powered and
controlled via a MESA Control Chassis as detailed in the MESA
Bulletin.
RJV/144 Mainframe - Rear View
RJV/48 Mainframe - Front View
RJV/144 Mainframe - Front View
FOR TECHNICAL ASSISTFOR TECHNICAL ASSIST
FOR TECHNICAL ASSISTFOR TECHNICAL ASSIST
FOR TECHNICAL ASSIST
ANCEANCE
ANCEANCE
ANCE
, PLEASE CONT, PLEASE CONT
, PLEASE CONT, PLEASE CONT
, PLEASE CONT
AA
AA
A
CT CYTEC ACT CYTEC A
CT CYTEC ACT CYTEC A
CT CYTEC A
TT
TT
T
800-346-3117 OR VISIT OUR WEBSITE A800-346-3117 OR VISIT OUR WEBSITE A
800-346-3117 OR VISIT OUR WEBSITE A800-346-3117 OR VISIT OUR WEBSITE A
800-346-3117 OR VISIT OUR WEBSITE A
T cytec-ate.comT cytec-ate.com
T cytec-ate.comT cytec-ate.com
T cytec-ate.com
RJV/48 Mainframe - Rear View
CONTROL
RS-232
UTP
LINK