Specifications
This manual control has a keypad and LCD display of last
command.
CX SERIES
COAXIAL AND RF
SWITCHING MATRIX
The CX Series of Switching Matrices are available in a variety of single wire coax con-
gurations designed to operate in the range from DC to 700 MHz with many options to
minimize price while meeting the desired specications.
CXG/8x8 50 ohm Mainframe
CX MAINFRAMES AND EXPANSION CHASSIS
BULLETIN
CX/8
CXB MAINFRAMES -- DC to 50 MHz
CX-1
Modular Systems with BNC connectors available in incre-
mental nonblocking congurations from 1x8 to 16x8, or from
2x4 to 32x4. 19" rackmount chassis, 3.5" high. See page
CX-2 of bulletin for complete specications.
CXE MAINFRAMES -- DC to 50 MHz
Modular Systems with BNC connectors available in incre-
mental nonblocking congurations from 2x8 to 32x8. 19"
rackmount chassis, 3.5" high. See page CX-2 of bulletin for
complete specications.
CXG MAINFRAMES -- DC to 700 MHz
Available as 4x8 or 8x8 nonblocking matrices in 50 or 75 ohm
characteristic impedance. Available with BNC, SMA or user
specied connectors. 19" rackmount chassis, 7" high. See
page CX-3 of bulletin for complete specications.
CXF MAINFRAMES -- 10 MHz to 500 MHz
Available as 4x8 or 8x8 nonblocking, full fan-out matrices
with 50 ohm characteristic impedance. Available with BNC,
or SMA connectors. 19" rackmount chassis, 7" high. See
page CX-3 of bulletin for complete specications.
CXL MAINFRAMES -- DC to 700 MHz
Affordable 8x8 blocking matrix with 50 ohm characteristic
impedance. Available with BNC, SMA or user specied con-
nectors. 19" rackmount chassis, 3.5" high. No LED indicators.
See page CX-4 of bulletin for complete specs.
MANUAL CONTROL OPTIONS
CONTROL OPTIONS
IF-5 IEEE488/RS232
This Module has both the IEEE488 (Talk /Listen) and the
RS232 features detailed in Applications Bulletin AP-5.
MC/2 KEYPAD MANUAL CONTROL W/ LCD DISPLAY
M/128-TW OR M/256-TW THUMBWHEEL CONTROLS
This manual control uses a thumbwheel selector and strobe
button to select switchpoints.
FREE CYTEC CONTROL SOFTWARE
IF-6 LAN INTERFACE
This Module uses Ethernet TCP/IP to provide control from a
Local Area Network to the Cytec RS232 port. It can be added
to existing IF-5C or IF-5 Control Modules to give an Ethernet
option or purchased with them so you can have all three control
interfaces (GPIB, RS232 and 10BaseT Ethernet).
IF-9 Ethernet LAN / RS232 Control for all CXM Chassis
This module has 3 ports available as 10/100 Ethernet and
an RS232 com port. All ports are available and active at all
times. Telnet default port 23 can be turned off.
Check out the latest version of free GUI software on our
webpage at: http://cytec-ate.com/support
The software runs on Windows XP or later. Source code
available on request.