Specifications
C2-6104A OPERATION MANUAL
77
14 CONNECTOR PINOUTS
14.1 DVI-I connector
PIN# SIGNAL PIN# SIGNAL
1 T.M.D.S DATA 2- 16 HOT PLUG DETECT
2 T.M.D.S DATA 2+ 17 T.M.D.S DATA 0-
3 T.M.D.S DATA 2/4 SHIELD 18 T.M.D.S DATA 0+
4 Not used 19 T.M.D.S DATA 0/5 SHIELD
5 Not used 20 Not used
6 DDC CLOCK 21 Not used
7 DDC DATA 22 T.M.D.S CLOCK SHIELD
8 ANALOG VERT. SYNC 23 T.M.D.S CLOCK+
9 T.M.D.S DATA 1- 24 T.M.D.S CLOCK-
10 T.M.D.S DATA 1+
11 T.M.D.S DATA 1/3 SHIELD C1 ANALOG RED
12 Not used C2 ANALOG GREEN / CV
13 Not used C3 ANALOG BLUE
14 +5V POWER C4 ANALOG HORZ SYNC
15 GND C5 ANALOG GROUND
14.2 RS232 / RS485 / RS422 D9 socket
Pin RS-232 RS-422
Full duplex
RS-485
Half-duplex
1 - TX- (from unit) A (link to pin 9)
2 TX (from unit)
3 RX (to unit)
4 - RX+ (to unit) B (link to pin 6)
5 GND GND GND
6 - TX+ (from unit) B (link to pin 4)
7 CTS (to unit)
8 RTS (from unit)
9 - RX- (to unit) A (link to pin 1)
‘To unit’ means signals are coming from a controller and being received by the unit.
‘From unit’ means signals are coming from the unit and being sent to a controller.
RS-422 may require termination across the RX+/- pins (usually 120 Ohm).
RS-485 needs pins linked as shown and may require termination across the A/B
pins (usually 120 Ohm).
You can select the serial standard in the ‘System’ menu.