C2-6104A OPERATION MANUAL C2-6104A Video Processor Operation Manual
C2-6104A OPERATION MANUAL TABLE OF CONTENTS 1 DISCLAIMER ................................................................................................ 1 1.1 Regulatory Agency Acceptance........................................................................... 1 1.2 FCC Statement.................................................................................................... 1 1.3 Manual Version Information................................................................................. 2 1.
C2-6104A OPERATION MANUAL 8.3.3 ‘Aspect adjust’ = ‘Pixel’ ...................................................................................... 21 8.4 Items Associated with the Adjust keyers group.................................................. 22 8.5 Items Associated with the Adjust borders group ................................................ 24 8.6 Items Associated with the Adjust sources group relating to source labeling....... 25 8.6.1 Tally / UMD module support ...........................
C2-6104A OPERATION MANUAL 11.1 There is no picture on the Output. ..................................................................... 71 11.2 The image is shifted and not fully viewable........................................................ 71 11.3 The output resolutions no longer appear as expected. ...................................... 71 11.4 There is excessive flicker on the Output. ........................................................... 72 11.5 The Output image is distorted............
C2-6104A OPERATION MANUAL 1 DISCLAIMER This product is intended for professional and/or home use. This product is not intended for use in a medical environment and does not have the required certifications for such use. Similarly, use aboard any aircraft or spacecraft while in flight or as an adjunct to any surface, airborne or marine navigation system or any offshore marine activity, including control of any watercraft, or any use similar to those specifically herein mentioned is prohibited.
C2-6104A OPERATION MANUAL Caution: This equipment is intended for use in the manner prescribed in the Instruction Manual. Any user changes or modifications not expressly approved by TV One Multimedia Solutions could void the user’s authority to operate the equipment. Connecting this equipment to external devices requires no specially shielded cabling for FCC compliance. The Instruction Manual shows or describes the proper connection of this equipment for operation that insures FCC compliance.
C2-6104A OPERATION MANUAL 2 IMPORTANT SAFETY INSTRUCTION To insure the best from this product, please read this manual carefully. Read these instructions Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarized or groundingtype plug. A polarized plug has two blades with one wider than the other.
C2-6104A OPERATION MANUAL If you did not receive the correct plug, DO NOT attempt to modify it. Instead, immediately contact your dealer or contact TV One at the sales office nearest to your geographic location and request the proper plug. 2. 1 Intellectual property Some IC chips in this product include confidential and/or trade secret property. Therefore you may not copy, modify, adapt, translate, distribute, reverse engineer, reverse assemble or decompile the contents thereof.
C2-6104A OPERATION MANUAL 2 CONSIGNE IMPORTANTE DE SECURITE Pour obtenir les meilleures performances avec ce produit, nous vous demandons de lire soigneusement ce manuel. Lisez ces consignes Ne procédez pas à une installation à proximité de sources de chaleur, quelles qu'elles soient, (radiateurs, registres calorifiques, fours, etc.
C2-6104A OPERATION MANUAL ! AVERTISSEMENT Pour réduire tout risque d'incendie ou de choc électrique, n'exposez pas cet appareil à la pluie ou à une humidité. Le câble d'alimentation secteur ou l'adaptateur remis avec cet appareil doit être conforme au type employé dans votre pays. Veuillez comparer l a prise de votre cordon électrique ou de votre adaptateur à la prise murale de l'emplacement où doit être installé votre appareil. Si vous n'avez pas reçu la bonne prise, N'ESSAYEZ PAS de la modifier.
C2-6104A OPERATION MANUAL 2 WICHTIGE SICHERHEITSANWEISUNGEN Lesen Sie diese Bedienungsanleitung sorgfältig, um zu gewährleisten, dass Sie den optimalen Nutzen aus diesem Produkt ziehen. Lesen Sie diese Anweisungen. Stellen Sie das Gerät nicht in der Nähe von Wärmequellen wie etwa Heizkörpern, Heizklappen, Öfen oder anderen Wärme erzeugenden Geräten (einschließlich Verstärkern) auf.
C2-6104A OPERATION MANUAL ! WARNUNG: Setzen Sie das Gerät weder Regen noch Feuchtigkeit aus, um die Gefahr eines Brandes oder elektrischen Schlags zu minimieren. Das mitgelieferte Netzkabel oder der mitgelieferte Adapter müssen dem in Ihrem Land verwendeten Typ entsprechen. Vergleichen Sie den Netzstecker oder Adapter mit der Netzsteckdose, an die das Gerät angeschlossen wird. Falls Sie nicht den richtigen Stecker erhalten haben, versuchen Sie NICHT, ihn zu ändern.
C2-6104A OPERATION MANUAL 2 INSTRUCCIONES IMPORTANTES DE SEGURIDAD Para garantizar el máximo rendimiento de este producto, lea cuidadosamente este manual. Lea estas instrucciones No lo instale cerca de fuentes de calor como radiadores, salidas de aire caliente, estufas u otros aparatos (incluyendo amplificadores) que produzcan calor. Respete la finalidad de seguridad de las clavijas polarizadas o con toma de tierra.
C2-6104A OPERATION MANUAL clavija en su cable o adaptador con la toma de corriente donde vaya a instalar la unidad. Si no ha recibido la clavija correcta, NO intente modificarla. Póngase inmediatamente en contacto con su distribuidor o con TV One en la oficina de ventas más cercana a su localización geográfica y solicite la clavija adecuada. 2.1 Propiedad intelectual Algunos chips con circuitos integrados presentes en este producto incluyen propiedad confidencial y/o secreta del sector.
C2-6104A OPERATION MANUAL 2 BELANGRIJKE VEILIGHEIDSINSTRUCTIE Om dit product optimaal te kunnen gebruiken, dient u deze handleiding aandacht te lezen. Lees deze instructies Plaats het apparaat niet in de nabijheid van warmtebronnen zoals radiatoren, kachels, warmtesensoren zoals thermometers, of andere apparaten (waaronder versterkers) die warmte afgeven. Omzeil het beveiligingsoogmerk van de gepolariseerde of geaarde stekker niet.
C2-6104A OPERATION MANUAL Het type wisselspanningkabel of adapter dat met deze eenheid is geleverd, dient overeen te komen met wat in uw land wordt gebruikt. Vergelijk de stekker van de kabel of adapter met het stopcontact waarop de eenheid wordt aangesloten. Als u niet de juiste stekker hebt ontvangen, breng dan zelf GEEN wijzigingen aan.
C2-6104A OPERATION MANUAL 2 VIKTIGA SÄKERHETSANVISNINGAR För att få ut det bästa av din produkt bör du läsa denna bruksanvisning noggrant. Läs dessa anvisningar Placera inte enheten nära värmekällor, som värmeelement, varmluftsintag, spisar eller annan utrustning (inklusive förstärkare) som producerar värme. Försök inte använda en stickkontakt i ett uttag som den inte är utformad att användas i. En polariserad kontakt har två blad – det ena bredare än det andra.
C2-6104A OPERATION MANUAL Om du inte fick rätt stickkontakt FÅR DU INTE försöka anpassa den. Kontakta i stället omedelbart butiken eller TV Ones närmaste försäljningsställe och be att få rätt stickkontakt. 2.1 Intellektuell egendom Vissa IC-chip i denna produkt innehåller konfidentiellt material och/eller företagshemligheter. Du får därför inte kopiera, modifiera, anpassa, översätta eller distribuera innehållet eller använda reverse engineering, assemblering eller dekompilering på det.
C2-6104A OPERATION MANUAL 2 VIKTIGE SIKKERHETSANVISNINGER For at du skal få mest mulig ut av dette produktet, ber vi deg lese denne håndboken nøye. Les disse anvisningene. Må ikke installeres i nærheten av varmekilder som radiatorer, varmeapparater, komfyrer eller andre apparater (også forsterkere) som produserer varme. Ikke sett sikkerhetsinnretningen til det polariserte eller jordete støpselet ut av funksjon.
C2-6104A OPERATION MANUAL Sammenlign støpselet på ledningen eller adapteren med stikkontakten der hvor enheten skal installeres. Hvis du har fått feil støpsel, må du IKKE forsøke å modifisere det. I stedet må du straks kontakte forhandleren eller nærmeste salgskontor for TV One og be om riktig type støpsel. 2.1 Opphavsrett Noen av IC-brikkene i dette produktet inneholder fortrolig informasjon og/eller fabrikkhemmeligheter.
C2-6104A OPERATION MANUAL 2 TÄRKEITÄ TURVALLISUUSOHJEITA Lue tämä opaskirja huolellisesti, jotta saat parhaan hyödyn tästä tuotteesta. Lue nämä ohjeet Älä asenna laitetta lähelle lämpölähteitä, kuten esim. lämpöpatteria, lämmitintä, uunia tai muita lämpöä tuottavia laitteita (vahvistimet mukaan lukien). Älä tee tyhjäksi polarisoidun tai maadoitetun pistokkeen turvallisuustarkoitusta. Polarisoidussa pistokkeessa on kaksi kosketuspiikkiä, joista toinen on leveämpi.
C2-6104A OPERATION MANUAL Jos laitteen pistoke on väärä, ÄLÄ yritä muunnella sitä. Ota heti yhteys jälleenmyyjään tai lähimpään TV One -myyntikonttoriin ja pyydä oikeaa pistoketta. 2.1 Immateriaaliomaisuus Jotkut tässä tuotteessa olevat IC-sirut sisältävät luottamuksellista ja/tai liikesalaisuusomaisuutta. Sen tähden sisältöä ei saa kopioida, muokata, kääntää, jakaa, takaisinmallintaa, mallintaa symbolisella konekielellä tai kääntää takaisin.
C2-6104A OPERATION MANUAL 3 CAPABILITY, DEVICE FEATURES AND PRODUCT FEATURES 3.1 Device Capabilities ® The C2-6104A uses four proprietary CORIO 2 scaling engines to perform its functions, offering a powerful toolset for any application requiring high quality video signal conversion or image manipulation. All units feature four video processing and scaling engines, with video mixing, keying, fading, and source-labeling capabilities.
C2-6104A OPERATION MANUAL processing hardware – the CORIO® 2 scaling engine. See http://www.tvone.com/support for more detail.
C2-6104A OPERATION MANUAL 4 PRODUCT IMAGES Your product should look like the unit below.
C2-6104A OPERATION MANUAL 5 UNPACKING AND INSTALLATION 5.1 Shipping Carton Your unit will arrive double boxed for maximum protection during shipping. You are encouraged to retain both boxes and all packing material so the unit can be returned in the unlikely event that repairs should ever become necessary. 5.2 Important Safety Instructions The AC power cable furnished with the unit should conform to the type in use in your country.
C2-6104A OPERATION MANUAL 6 FRONT PANEL CONTROLS The range of buttons on the front of the unit provides the user with quick access for selecting a variety of inputs and features. The cross-hair (up/down/left/right) buttons on the front panel provides the user with a way of navigating the Liquid Crystal Display menus (LCD) which is detailed in a later section. 6.
C2-6104A OPERATION MANUAL 6.2 Menu navigation buttons The LCD is controlled from the front panel by using these buttons. These functions let the user navigate through the menu structure or change a parameter, and are detailed in a later section. 6.3 Advanced menus System Advanced menus [Off] The above menu item must be ‘On’ to activate certain menu items. These typically control the more advanced items in the menus. 6.
C2-6104A OPERATION MANUAL All stored settings except resolutions are lost when the unit is reset. A Firmware update is the only way to perform a complete factory reset (including resolution data). 6.4.
C2-6104A OPERATION MANUAL 7 VIDEO INPUTS AND OUTPUTS 7.1 C2-6104A This unit has 4x DVI-U inputs, 1x DVI-U background input and 1x DVI-I output. 7.2 Computer & Video inputs Signal DVI-U input Analog RGBHV RGsB (sync on green) RGBS (composite sync at TTL levels) YUV/YPbPr (including tri-level) DVI-D HDMI sources Composite Video (on green) Analog and HDMI sources will need an adaptor or cable to convert the DVI-I connector to the relevant connector for your source.
C2-6104A OPERATION MANUAL Signal DVI-I output Analog RGBHV RGsB (sync on green) RGBS (composite sync at TTL levels) YUV/YPbPr (including tri-level) DVI-D This is altered in the ‘Adjust outputs’ menu, where the user can select between the above outputs. The DVI-D output is always active and follows the color-space of the analog signal. YUV/YPbPr (component) outputs can also be switched to RGsB (sync on green) mode if desired -see ‘Adjust outputs’ in this manual for more information. 7.
C2-6104A OPERATION MANUAL The resulting windows are merged together into a single output, according to the layer priority as set in Adjust windows. Not shown in the above diagram are the Still Image Stores (SIS1 through to SIS4) which can provide a static source for the Windows A through D (but not background Z), nor the border generators which can place borders of any color or opacity around each window.
C2-6104A OPERATION MANUAL 8 MENU LAYOUT AND SETTINGS ADJUSTMENT From here on, we’ll be looking at the menu structure and, more importantly, the individual menu items that allow you to take advantage of the power of the unit. You’ll be using the menu navigation buttons and the Liquid Crystal Display (LCD) to view the options and settings available to you. First press the left / right buttons to see where you are in the menu. Go into a sub menu by pressing the SELECT button once.
C2-6104A OPERATION MANUAL In some cases the functionality is global – meaning it has an effect on the unit as a whole (such as changing the output resolution). In the majority of cases, the function is related to a specific operational area of the unit, detailed by the text in the top line. There are two screens that appear before the Group Menus (sub-menus) are accessed. CORIO2 TV One The first is the ‘welcome’ display shown above indicating the model of the unit. www.tvone.com SW: 65.
C2-6104A OPERATION MANUAL 8.2 Items Associated with the Adjust outputs group This menu group allows adjustments to be made that specifically affect the output of the unit, including output resolution and locking/overlaying onto a computer or video source. 800 x 600 60Hz Lock mode [Off] [RGB1] This menu item allows the lock mode to be selected and the lock source to be defined. The top line of the display shows the current detected resolution of the selected lock source (RGB1 in this example).
C2-6104A OPERATION MANUAL Before turning the Lock feature on, you first must select a valid Lock source. Some units may not have all Lock sources available, depending on hardware limitations – see Specifications for details of limitations on your unit. If the Lock source you choose is not valid, then Genlock or Lock & Mix will be temporarily disabled, until the Lock source becomes valid again. When disabled, the resolution previously specified in ‘Output res’ becomes the output resolution.
C2-6104A OPERATION MANUAL Status message No display Unavailable Supported Active Rep. supprt Rep. active Description Effect There is no display attached (HOTPLUG is low). The device attached is not capable of support ing HDCP. Nothing will be output on the DVI connector. The device attached is capable of HDCP, but the output is not currently encrypted. The device attached is capable of HDCP, and the output from the unit is encrypted. The repeater unit (e.g.
C2-6104A OPERATION MANUAL source’s input – hence it should be turned Off it the CV/YC outputs are going to be used. Adjust outputs Stand. [NTSC-M/PAL-BDGHI] This menu item is only available when the Output resolution is set to PAL or NTSC. With this you can change the output type to the PAL or NTSC standard with the further option of changing the output to the additional PAL & NSTC standards such as PAL-M or PAL-N.
C2-6104A OPERATION MANUAL This menu item only appears on units with multiple windows or PIPs. It is used to select which one you want to modify. Alternatively, use one of the dedicated buttons on the front panel to choose the window to adjust. NTSC / 60Hz Source [ YC1] The source display screen allows the input source for the currently selected window to be changed. The top line of the display shows the detected characteristics of the signal.
C2-6104A OPERATION MANUAL By adjusting the H/V values, you can crop out the black areas to correct the size on the final output screen. Note that it does not change the shape or aspect ratio of the image – but just removes the parts of the image that are not required. Adjust windows H/V out shift [ 0] [ 0] This positions the selected Window horizontally and vertically on the monitor.
C2-6104A OPERATION MANUAL This is a feature only present in advanced units only. It greatly improves the method of frame-rate conversion, by allowing the unit to merge frames together during the process. When ‘Off’, the unit will use frame-repetition when converting 50Hz to 60Hz (i.e. it has to duplicate every 5th frame), or frame-dropping when converting 60Hz to 50Hz (i.e. it has to drop every 6th frame).
C2-6104A OPERATION MANUAL Adjust windows Audio bars [4] Certain units can display audio bar measurements and this menu item displays how many stereo-bars are shown. A maximum of 4 stereo bars (8 bars in total, with leftright pairs next to each other) can be shown. Audio channels are always numbered from left to right, balanced to display bars on both sides of the each. A setting of 0 disables the audio bars from being shown.
C2-6104A OPERATION MANUAL Simple Zoom level % [100] H/V zoom pan% [50] 50 H/V crop % [ 0] 0 Shrink level % [50] Off H/V position % [50] 50 8.3.2 Advanced Pixel Zoom H/V [100]100 1.333:1 In [ 0],0 640,480 H/V zoom pan% [50] 50 Out [ 0],0 640,480 H/V crop % [ 0] 0 ShrnkH/V [50] 50 1.333:1 H/V position % [50] 50 ‘Aspect adjust’ = ‘Advanced’ Adjust windows H/V zoom % [100] [100]1.333:1 This item allows the independent setting of the horizontal and vertical zoom values. The third number (1.
C2-6104A OPERATION MANUAL placed in the output video signal – in other words the ‘In’ and ‘Out’ positions and sizes. The diagram below should help to clarify the function of these values: 0 1024 0 1024 0 0 OUT IN 768 768 In the example above, ‘In’ has been set to 300,150 as its top-left source coordinate, with a size of 750,400. ‘Out’ has been set to 50,50 (i.e. close to the top left) with a size of 250,300.
C2-6104A OPERATION MANUAL Normally, your foreground is the input (window) source and your background is the lock source. This then allows you to superimpose any graphics or video input on top of the lock source by keying out a certain color or range of colors in the input source. Swapping them means that the input source moves to the background and the lock source is now in front of it. Thus you are now keying out the lock source colors to reveal the input source behind it.
C2-6104A OPERATION MANUAL Setting it to Off will cause the colour range that’s defined to be removed - remove the desired colors. Setting it to On will cause the colour range that’s defined to be kept - key out all other colors. The descriptions above behave identically on the remaining U Key Invert & V Key Invert component versions. However they are directed at the U/B-Y (blue) colour component and V/R-Y (red) colour components respectively.
C2-6104A OPERATION MANUAL Adjust borders Brdr opacity % [100] This parameter controls how visible the border is to the viewer. A setting of 0 renders the border invisible (transparent) whereas a setting of 100 makes the Logo fully visible. (In-between settings can give the Border a transparent appearance.) 8.6 Items Associated with the Adjust sources group relating to source labeling The ‘Adjust Sources’ menu group accesses the parameters associated with each input present on your unit.
C2-6104A OPERATION MANUAL This menu item controls where the source label will appear within the window that uses this source. H position options: Off, Left, Center, Right V position options: Off, Top, Middle, Bottom When either of the options are set to ‘Off’, no source labelling will be shown. Label char [ 1] ( 068) DVI-I1 In this menu item, you can change the text shown when this source is used.
C2-6104A OPERATION MANUAL This menu item allows the font, H-Size and V-Size of the characters to be altered. If you make the font size too big, it may become corrupted or disappear. 8.7 Items Associated with the Adjust sources group The ‘Adjust Sources’ menu group accesses the parameters associated with the processing amplifiers used for each input (RGB, CV, YC, etc.). They allow you to fine-tune an incoming signal to optimize its color, brightness or even sharpness.
C2-6104A OPERATION MANUAL Setting Fill (default) Aspect H-fit V-fit 1:1 Result The source is stretched to fill the output. The source’s aspect ratio is maintained on the output. The source is stretched to fill the horizontal dimension of the output, with the vertical dimension stretched by the same amount (and possibly clipped). The source is stretched to fill the vertical dimension of the output, with the horizontal dimension stretched by the same amount (and possibly clipped).
C2-6104A OPERATION MANUAL In most situations, the Audio input values would be different for each video source – so that when the first video source is selected, so is the first audio source (this is called ‘audio follow video’). The second video source then selects the second audio source, etc. However, there is nothing to prevent all Audio input values being set to the same value, for ‘audio breakaway’.
C2-6104A OPERATION MANUAL Mode Normal/weave Auto Film 3:2 M. Comp Low M. Comp Med. M. Comp High Frame/bob Function The two interlaced fields are simply combined/weaved together. This will often show artifacts on moving images, but can be used when the input is known to be still. Automatically selects Film 3:2 or Medium Range Motion Compensation (M. Comp Med.) depending on whether Film Mode is detected or not. Enables 3:2 pull down conversion of the incoming NTSC video.
C2-6104A OPERATION MANUAL Status message Inactive Active Description Effect HDCP is not active at the DVI connector. HDCP is active at the DVI connector. HDCP-encrypted material cannot be received by the unit. HDCP-encrypted material can be received by the unit, but only if a HDCP-compliant display or device is attached to the unit’s output. See ‘Adjust outputs’ for a description of how the HDCP system works on your scaler. Source: DVI1 Display emul.
C2-6104A OPERATION MANUAL It should also be noted that some graphic cards will require your PC to be re-booted before they see that a change has occurred. If your unit allows ‘HDMI’ to be selected, this can also enable certain audio features depending on the abilities of your unit.
C2-6104A OPERATION MANUAL pixel phase adjustment allows you to change the position (from 0 to 31) where the pixels are sampled, relative to the horizontal sync signal. To make this adjustment, select an RGB source and then provide an image from that source with fine detail, preferably with very sharp vertical lines. Adjust this value until you see the sharpest image. Alternately, adjust this value to give the worst (noisiest/softest) image, and then add or subtract 16 to get the optimum value.
C2-6104A OPERATION MANUAL Saturation is the amount of color present in the image. Hue is the color “tint” parameter and the adjustment range is +90 degrees through to -90 degrees with 0 being the default. Source: YC1 Sharpness [0] Within limits, you can enhance or soften the appearance of detail within an image. The Sharpness values go both negative and positive, with 0 being the default.
C2-6104A OPERATION MANUAL Adjust transitions Transition [Fade] This first adjustment controls the type of transition desired: ‘Cut’, ‘Fade’, ‘Wipe’ or ‘Push’. If you select ‘Cut’ or ‘Fade’, the only remaining menu items will be ‘Switching Fade Time’ and ‘Exit’. Selecting ‘Wipe’ or ‘Push’ exposes additional parameters. Adjust transitions Switching fade time [ .5] This parameter controls how long a transition from one input to another takes.
C2-6104A OPERATION MANUAL Tally / GPIO connections are connected via a D25 socket: 13 5v 12 TX+ TX25 11 RX+ RX24 10 GND GND 23 9 TI8 TO8 22 8 TI7 TO7 21 7 TI6 TO6 20 6 TI5 TO5 19 5 TI4 TO4 18 4 TI3 TO3 17 3 TI2 TO2 16 2 TI1 TO1 15 1 GND GND 14 Note that the TX+/- and RX+/- pins are duplicates of the RJ45 connector and support RS-422/485, as per the TSL specification.
C2-6104A OPERATION MANUAL In Normal mode, the borders are set as follows: Tally input pin pulled low TI1 TI2 TI3 TI4 TI5 TI6 TI7 TI8 Activation result on a 4-window system Window A has a red border Window A has a green border Window B has a red border Window B has a green border Window C has a red border Window C has a green border Window D has a red border Window D has a green border Please note that you may need to reduce the window size in order to see the full colored border.
C2-6104A OPERATION MANUAL In most networks, all computers and other electronic equipment will have a dedicated connection to a network hub or switch, with each item having its own ‘IP address’ (Internet Protocol address). This is the unique set of numbers that identifies the item on the network. The network itself is usually segmented into a number of sub-networks.
C2-6104A OPERATION MANUAL Enter 4 numbers one by one to form the IP address you wish to assign to the unit. The IP address is a series of four numbers between 0 and 255. Anything above 255 is not a valid number in an IP address range. The unit will not allow you to go above 255. The IP address must be a unique address on your network, and also must be within the sub-net of your network. If you are unsure about which IP address to use or don’t have a unique IP address, ask your Network Administrator.
C2-6104A OPERATION MANUAL DO NOT ADJUST THESE ITEMS UNLESS YOU’RE CERTAIN YOU KNOW WHAT YOU’RE DOING! THE ONLY METHOD TO UNDO CERTAIN CHANGES IS TO UPDATE THE FIRMWARE. TRY USING THE AUTOSET, SHRINK, SHRINK POS, TL & BR ADJUSTMENTS FIRST. Making adjustments here risks creating a non-standard resolution that is not displayable on a monitor. The resolutions and values within the database are industry standards and should not normally be altered by the user.
C2-6104A OPERATION MANUAL The H.freq.fine (Horizontal Sync Frequency) adjustment provides the option for changing the Horizontal Sync timing Frequency in 1 Hz steps. Use this option to fine tune after using the course adjust. Please note that the internal sync generator may be unable to generate the exact frequency you want. 800 x 600 60 Hz Clks/l [1056] = 40.000MHz This option changes the total number of image pixels on one line of monitor video including the Horizontal sync pulse and blanking time.
C2-6104A OPERATION MANUAL Porch have a direct bearing on where the active (visible) portion of the image begins. Do not attempt this adjustment without monitoring the results with an oscilloscope. 800 x 600 60 Hz H/V Sync [ 128] x 4 There are standards for all current computer and broadcast resolutions that specify the correct width of both Vertical and Horizontal synchronizing pulses.
C2-6104A OPERATION MANUAL designators and cannot be changed by the user however both designators are important to support personnel. System SW date: 2006-7-11 This is an information page showing when the currently installed software was released. The information is useful to the user as he or she compares the date to the website information describing the current software release.
C2-6104A OPERATION MANUAL System OSD on power up [On] This parameter controls whether the ‘welcome’ screen is displayed or not on power up for units with an on-screen display – it can be disabled as required. This is useful when a unit is installed as part of an overall system. System LED brightness % [ 90] This parameter is available on certain units and controls how bright the LEDs on the front panel appear.
C2-6104A OPERATION MANUAL System Buzzer [ On] The screen labeled ‘Buzzer’ is actually the control for turning the “Beep” “On” or “Off”. Normally this is left in the “On” position to provide positive feedback that your data entries and parameter changes have been accepted. System CC-300 A/B bus mode [ Off] This menu item changes the function of an attached CC-300 CORIOconsole unit.
C2-6104A OPERATION MANUAL System Hours in Use 877 This is another informational display for usage audit purposes. System Temp.C 30 33 43 45 Certain units have built-in temperature sensors, and if yours has such a feature then the above menu item will appear. If the ambient temperature of the internal components becomes excessively high or low, the unit will shut down to prevent harm.
C2-6104A OPERATION MANUAL 9 SERIAL PORT 9.1 Connection Your unit is fitted with a standard ‘D9’ plug or socket allowing it to be controlled from a computer or other type of terminal or console with a similar interface. Most computers fitted with an RS232 port, known as a ‘COM’ port, will have a ‘D9’ plug on them.
C2-6104A OPERATION MANUAL Note: Any command you send to the unit will be replied to either with an error code or with the actual changed value. This may be different to the one you sent; for example, if trying to set a value too high or too low.
C2-6104A OPERATION MANUAL 10 SERIAL / IP CONTROL SPECIFICATION PLEASE NOTE: Not all units support Serial and/or IP (Ethernet) communications – check to see if this feature is present on your unit. This section outlines how to control a unit via a Serial or Ethernet link (if fitted to your unit), using ASCII-based commands. It details how to send and receive serial data to perform many of the functions that a user has access to on the unit.
C2-6104A OPERATION MANUAL The ACK flag will be returned as 0 if the command is invalid for some reason – for example a bad FUNCTION, WINDOW, OUTPUT or PAYLOAD value. An ACK=0 message will be otherwise identical to the one you sent, so you know exactly which message has the error. Any changes made to the unit using the front panel controls will also cause the full 20 byte message to be sent indicating the change that has occurred, thus enabling a program to stay ‘in-sync’ with the unit.
C2-6104A OPERATION MANUAL CHA (Channel) SOURCE returned means message was okay. ACK=0 returned means an error was present in the message. Bit 5 = 0 Reserved for future use. Bit 4 = 0 Reserved for future use. Bit 3 = 0 Reserved for future use. Bit 2 = 1 This bit *must* be set. Bit 1 = 0 Reserved for future use. Bit 0 = 0 Reserved for future use. This byte has multiple uses, and defaults to 0 unless used for: CHA When a channel number is used in the Adjust Sources section (see later).
C2-6104A OPERATION MANUAL CS ASCII-hex byte that is the (check) sum of all previous bytes (excluding the SOP 'F' character). E.g. The command F0400410082000001C8 has the checksum of 04+00+41+00+82+00+00+01=C8, so the complete command to send is F0400410082000001C8. A short-cut for debugging allows the checksum to be replaced by 2 question marks, so in the previous example you could send F0400410082000001?? Instead.
C2-6104A OPERATION MANUAL Adjust outputs Output enable Lock source (connector) 170 149 Lock method 10A Lock H Shift Lock V Shift Output resolution Output image type Output image type digital 14A 14B 083 HDCP required HDCP status 233 234 Background Y Background U Background V SDI optimization Output Standard 13B 13C 13D 197 101 Output CV/YC IRE Output CV/YC Hue (degrees) Output SC/H Phase Output Luma Bandwidth Output Chroma Bandwidth Output Chroma delay PAL WSS 133 139 0=Blanked, 1=Active 0x10 t
C2-6104A OPERATION MANUAL Take 11E Audio amp. Volume AES/SDI Chan. 1 source AES/SDI Chan. 2 source AES/SDI Chan. 3 source AES/SDI Chan. 4 source AES/SDI Chan. 5 source AES/SDI Chan. 6 source AES/SDI Chan. 7 source AES/SDI Chan.
C2-6104A OPERATION MANUAL In (top-left H) In (top-left V) In (H size) In (V size) Out (top-left H) Out (top-left V) Out (H size) Out (V size) Aspect change Aspect adjust Flicker reduction Image smoothing Image flip Temporal interpolation Show source label Audio bars Max fade level Fade out / in 21B 21D 21C 21E 21F 221 220 222 190 102 092 0A1 095 229 250 252 10F 193 Layer priority Headphone volume Audio vol. (volume) Audio vol. (on/off) 144 0FD 206 207 0..2 = Normal, Letterbox, Pillarbox 0..
C2-6104A OPERATION MANUAL E.blnd size H E.blnd size V E.blnd gamma H E.blnd gamma V E.blnd comp cent E.blnd comp side 18B 18C 188 18D 198 19D 0.. limited by H width 0.. limited by V height 1..150 1=0.01, 150=1.50 1..150 1=0.01, 150=1.50 0..99 0..99 Logos (on certain models only) Logo enable Logo number H/V out shift (H) H/V out shift (V) Max fade level Layer priority 12B 143 0AD 0AE 10F 144 0..1 = Off, On 0..9 Logo selection 0..100 % 0..100 % 0..100% 0..
C2-6104A OPERATION MANUAL Label H. Size Label V. Size Label H. Position Label V. Position Label char. to adj. Label char. value EDID to use EDID capture entry# EDID capture Grab HDCP advertise (DVI) HDCP status (DVI) TL pos. adj. (left) TL pos. adj. (top) BR size adj. (right) BR size adj. (bottom) Audio input source (internal) OPTION audio input Audio vol Bal On source loss (was Deglitch) Source stable (read only) Input pixel phase RGB input type 10..5F 10..5F 10..5F 10..5F 10..5F 10..5F 10..1F 10..1F 10..
C2-6104A OPERATION MANUAL (Film mode detected) 10..FF 0E3 Diagonal interpolation 10..FF 22B Noise reduction 10..5F 23F Bright 30..5F 0BB Contrast 30..5F 0BC Saturation 30..5F 0B9 Hue 30..5F 0BA Sharpness 30..5F 080 Luma delay 30..5F 0BD Field swap 10..FF 0C9 Field Offset 10..FF 196 For units with digital audio processing: Audio channel 1 10..FF 213 Audio channel 2 10..FF 214 Audio channel 3 10..FF 215 Audio channel 4 10..FF 216 Audio channel 5 10..FF 217 Audio channel 6 10..FF 218 Audio channel 7 10..
C2-6104A OPERATION MANUAL Tally input number Tally preset to load 261 262 1 = Normal 2 = Presets 1 to 8 1 to 50 Adjust resolutions Note: You MUST set the 'Image to adjust' value to the correct value first, and only then change the other values - otherwise you may be adjusting the wrong entry. The user should not adjust the 'Image to adjust' entry using the front panel whilst also accessing it via RS232 Image to adjust 081 1..
C2-6104A OPERATION MANUAL Number of logos Board temp. (deg.C) Air temp. (deg.C) Regulators temp.(deg.C) PLD temp. (deg.
C2-6104A OPERATION MANUAL SOP CMD CHA WIN OUT FUN PAY CS EOP SOP CMD CHA WIN OUT FUN PAY CS EOP Set output 1 window B Source to RGB2 F 04 00 42 00 82 000011 D9 CR F 44 00 42 00 82 000011 19 CR Set output 1 window A to Enable advanced aspect control Note checksum is ?? for debugging F 04 00 41 01 02 000001 ?? CR F 44 00 42 01 02 000001 8A CR Set 1A Shrink to 110 – invalid max for shrink is 100 F 04 00 41 00 87 00006E ?? CR F 44 00 41 00 87 000064 70 CR Read 1C Zoom level – invalid
C2-6104A OPERATION MANUAL Menu text Macro Run macro Number of items within macro Function to adjust Value CHA FUNC Range of adjustment (decimal) (Hex) 0..7 F1 0..7 F4 0..1 = Run, Erase macro Read Only 0..7 F2 0..7 F3 0..4095 Value for Function 10.5.1 Reading a previously stored Macro In order to read a macro the following commands must be sent in this specific order – no other commands should be sent between these messages.
C2-6104A OPERATION MANUAL F 04 02 42 00 F1 000001 3A CR F 44 02 42 00 F1 000001 7A CR Write the function for first item in macro 3 = Zoom F 04 02 42 00 F3 000086 C1 CR F 44 02 42 00 F3 000011 01 CR Write data for the first item = 100 F 04 02 42 00 F2 000064 9E CR F 44 02 42 00 F2 000011 DE CR Write the function for the second = shrink F 04 02 42 00 F3 000087 C2 CR F 44 02 42 00 F2 000011 02 CR Write the data for the second item = 100 F 04 02 42 00 F2 000064 9E CR F 44
C2-6104A OPERATION MANUAL Set to 720p 59.
C2-6104A OPERATION MANUAL Run Macro 5 Run Macro 6 Run Macro 7 Add to Macro 1 Add to Macro 2 Add to Macro 3 Add to Macro 4 Add to Macro 5 Add to Macro 6 Add to Macro 7 Erase Macro 1 Erase Macro 2 Erase Macro 3 Erase Macro 4 Erase Macro 5 Erase Macro 6 Erase Macro 7 Decrease Horizontal Pan value Increase Horizontal Pan value Decrease Vertical Pan value Increase Vertical Pan value Select window A Select window B Select window C Select window D Select window Z Select Output 1 Select Output 2 SELECT (menu adjust
C2-6104A OPERATION MANUAL Select CV1 as source for window A Select CV2 as source for window A Select CV3 as source for window A Select YC1 as source for window A Select YC2 as source for window A Select YC3 as source for window A Select TC1 as source for window A Select TC2 as source for window A Select OUT1 as source for window A Select OUT2 as source for window A Select SDI1 as source for window A Select SDI2 as source for window A Select SDI3 as source for window A Select SDI4 as source for window A Sele
C2-6104A OPERATION MANUAL Select RGB2 as source Select YUV1 as source Logo 1A toggle on/off Logo 2B toggle on/off Window 1A toggle on/off Window 2B toggle on/off Go to Lock menu item Output 1 toggle on/off Output 2 toggle on/off Select UNI1 as source for window A Select UNI2 as source for window A Select UNI3 as source for window A Select UNI4 as source for window A Select UNI5 as source for window A Select UNI6 as source for window A Select UNI7 as source for window A Select UNI8 as source for window A Sel
C2-6104A OPERATION MANUAL Erase Preset 3 Erase Preset 4 Erase Preset 5 Erase Preset 6 Erase Preset 7 Erase Preset 8 Erase Preset 9 Erase Preset 10 Set output to BLACK Set output to WHITE Toggle edge blend lines on/off Cycle scaler inputs 280193 280194 280195 280196 280197 280198 280199 28019A 00029B 00029C 00029D 0002A3 I.e. insert the 6 digit code from above into the following text string: F041041024F######?? E.g. to Load Preset 1, use the text string: F041041024F000291?? 10.5.
C2-6104A OPERATION MANUAL COMMON OPERATIONS This section provides step by step instructions for some common operations. 10.6 Operation of the Keyer Some units come equipped with a very powerful Luminance and Chrominance Keyer. The Keyer can take some time to master and below is a breakdown and series of simple steps to help you master the Keyer’s operation When adjusting the values, please bear in the mind the following: The Y value is the Luminance value, so 0 is black and 255 is very bright (white).
C2-6104A OPERATION MANUAL to decrease the ‘min’ values and increase the ‘max’ values to broaden the range of colors keyed out. At this point, only the key color should remain transparent.
C2-6104A OPERATION MANUAL 11 TROUBLESHOOTING AND TECHNICAL SUPPORT If problems are experienced, please read through the symptom topics below in order to resolve the problem. After doing so, if you still need to, contact Technical Support at http://www.tvone.com/support. Please have the following details of the problem handy: Whether the problem happens only at specific times or has only just started occurring (and what other things have changed at the same time).
C2-6104A OPERATION MANUAL 11.4 There is excessive flicker on the Output. Try using a different Flicker reduction mode. Turning the contrast down and the brightness up on the output device can have a large effect on flicker. Or try adjusting the brightness and contrast of the source input by selecting the Input adjust menu. 11.5 The Output image is distorted. This may occur where some of the areas of the image are very dark and others are very bright.
C2-6104A OPERATION MANUAL 11.11 The RGB input is selected but the image is rolling or pink. Check the Adjust sources menu and confirm that the input type and sync method is set correctly. (Having YUV input selected, instead of RGBHV often causes this problem). 11.12 The video signal from my DVD player does not appear to work. Some DVD players have a switch at the back that selects between ‘Component’ and ‘S-Video’ output, because most will not let you output both at the same time.
C2-6104A OPERATION MANUAL 12 RETURN PROCEDURE Before returning your unit for repair, there are several checks you can make yourself to make sure the problem is actually caused by a failure. 12.1 Are you sure there's a fault? Many 'faults' are due to incorrect set-up or use so a simple checklist is provided below to help you identify potential problems. Set the unit up with your equipment as described in this manual and run through the checklist.
C2-6104A OPERATION MANUAL Please clearly state the return number on the outside packaging and on any accompanying documentation. This will greatly speed up processing. IMPORTANT: DO NOT return a unit for warranty repair without first obtaining a Return Authorization Number.
C2-6104A OPERATION MANUAL 13 WARRANTY POLICY LIMITED WARRANTY – With the exceptions noted in the next paragraph, TV One warrants the original purchaser that the equipment it manufactures or sells will be free from defects in materials and workmanship for a period of five years from the date of purchase. Should this product, in TV One’s opinion, prove defective within this warranty period, TV One, at its option, will repair or replace this product without charge.
C2-6104A OPERATION MANUAL 14 CONNECTOR PINOUTS 14.1 DVI-I connector PIN# 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 14.2 SIGNAL T.M.D.S DATA 2T.M.D.S DATA 2+ T.M.D.S DATA 2/4 SHIELD Not used Not used DDC CLOCK DDC DATA ANALOG VERT. SYNC T.M.D.S DATA 1T.M.D.S DATA 1+ T.M.D.S DATA 1/3 SHIELD Not used Not used +5V POWER GND PIN# 16 17 18 19 20 21 22 23 24 SIGNAL HOT PLUG DETECT T.M.D.S DATA 0T.M.D.S DATA 0+ T.M.D.S DATA 0/5 SHIELD Not used Not used T.M.D.S CLOCK SHIELD T.M.D.S CLOCK+ T.M.D.
C2-6104A OPERATION MANUAL 78
C2-6104A OPERATION MANUAL 15 SPECIFICATIONS See product front and rear diagrams for details of product I/O. 15.1 Computer Input DVI-D (on DVI-I connector) supporting up to 162MHz (1920x1200 @ 60Hz). HDCP support. EDID 1.3 data on DVI-D connector to communicate available resolutions. Analog RGB/YPbPr supporting RGBHV, RGBS, RGsB, YPbPr, auto-terminating into 75 Ohm Digital sync (in RGBHV or RGBS mode): TTL Level, 10K termination, pos or negative Analog sync (in RGsB, YPbPr, YUV modes): 0.3v negative.
C2-6104A OPERATION MANUAL 15.6 Scaling / sampling / memory Size and position: automatic via AutoSet or Manual Image size: 50 user-definable presets (presets 6 to 10 pre-defined) Image freeze: one video frame Settings memory: non-Volatile Zoom range: variable to 10x Zoom (1000%) Shrink range: variable to 10% Image mirroring: Horizontal and/or Vertical Horizontal filtering: full digital Conversion technology: proprietary Color resolution: 24-bit RGB (16.8 Million Colors), 20-bit 4:2:2 YCbCr processing.
C2-6104A OPERATION MANUAL (The unit is not compatible with the CC-300 CORIOconsole unit.) 15.13 Mechanical Size (H x W x D): 1.725” x 17” x 7.92” (44 x 431 x 201mm) Weight (Net): 7.0 lbs (3.2 kg) 15.
C2-6104A OPERATION MANUAL 16 CONTACT INFORMATION Should you have and questions or require assistance with this product in areas not covered by this manual, please contact TV One at the appropriate location shown below: TV One USA 2791 Circleport Drive Erlanger, KY 41018 USA Tel 859-282-7303 Fax 859-282-8225 sales@tvone.com www.tvone.com TV One Europe Continental Approach Westwood Industrial Estate Margate, Kent CT9 4JG, UK Tel +44 (0)1843 873311 Fax +44 (0)1843 873312 sales.europe@tvone.com www.tvone.