User guide
Chapter 6 Configuring the Sender
VideoJet 10 65
With monostable operation, the delay time can be selected after which the relay
reverts to its idle state.
You can choose various events that activate the output automatically. Thus, for
example, it is possible to switch on a spotlight in response to a motion alarm and
switch it off again when the alarm situation is no longer active.
Idle state:
Select Open if the relay is to operate as a normally open contact or Closed if it
is to operate as a normally closed contact.
Operating mode:
Select an operating mode for the relay.
If, for example, a light switched on by an alarm is to remain lit when the alarm has
ended, select Bistable. If an audible signal activated by an alarm is to sound for
a period of ten seconds for example, select 10 sec.
Relay follows:
Select a particular event to trigger the relay. The following events can activate the
relay:
] Off
No relay triggering by events
] Connection
Triggering caused whenever a connection is established
] Video alarm
Triggering caused by loss of the video signal
] Motion alarm
Triggering caused by the motion alarm
] Local input 1
Triggering caused by the alarm input 1
] Remote input 1
Triggering caused by a relay contact at the target location (only when a
connection is established)