User guide
Configuring the Sender Chapter 6
60 VideoJet 10
Note
Sender and receiver must share the same subnet for connection set-up
(see page 69).
Connect on alarm:
Select On for the VideoJet 10 to establish a connection automatically to a
specified IP address in the event of an alarm.
With the setting Follows input 1, the VideoJet 10 holds the automatically set up
connection to a remote location as long as an alarm signal is present at the alarm
input 1.
Number of destination address:
Here you assign the numbering for the IP addresses to be contacted in the event
of an alarm. The unit contacts the remote locations one after the other in the
numbered sequence until a connection has been established.
Destination IP address:
For each number, enter the corresponding IP address of the desired remote unit.
Destination password:
Enter the password, if the remote unit is protected by a password.
Auto-connect:
Select On if an active connection should be reestablished automatically to one of
the previously specified IP addresses after each restart, e.g. after a connection
breakdown or network dropout.