User guide

Configuration using a Web Browser Chapter 5
94 VideoJet 8000
Encoder number:
This shows information about the number of the associated encoder. The number
corresponds to the respective camera input on the back of the unit.
Type of recording:
You can change the recording mode as required. In Ring mode, recording will
continue indefinitely. When the maximum hard drive space has been reached,
the oldest recordings will be overwritten automatically. In Linear mode, recording
will continue until all the drive space has been used. Then recording will be
stopped until some old recordings are deleted to provide free space.
Recording data rate:
Select the desired recording rate here. The image quality increases automatically
as the data rate increases. However, a higher data rate reduces the recording
duration on the partition.
The maximum remaining recording time is recalculated after the data rate has
been set and is displayed further down the page (Remaining for recording).
Recording resolution:
Here you can change the image resolution for the recording as required.
Alarm input sources:
Here you can select the alarm sensors that should trigger an alarm. Select the
checkboxes of the alarm sources so the corresponding alarm sensors will be
monitored for alarm recording.
Note
A motion or video alarm from one camera can be used to trigger alarm
recording by another camera. The motion alarm must be configured on the
Motion Detector page (see page 98). Alarm inputs and the video alarms
are activated on the Alarm sources page (see page 96).
Partition total size:
The displayed value shows the total space in MB occupied by the partition on the
hard drive.