Instruction manual
86 © 2008 VBrick Systems, Inc.
Scripting Notes
• * denotes end of group.
• Each group can have a maximum of six sets.
• Each group must have apply sets for all normal sets.
• Wait state will be alone in a group.
• There is no clear command.
• Script commands must start in column 1.
• There is no chaining of scripts.
• Comments will start with / and can be a line or the end of a command.
• All scripts are executed in a strictly serial manner by a single task.
• While executing a script it is possible to miss a double change of any event.
Configuration: Script Management > Auto Configuration
Auto Config lets you perform an auto-configuration via a URL script file. It is typically used 
for remote configuration and troubleshooting or to configure VBrick appliances that are 
behind a firewall. To configure a parameter on an appliance (or more likely a set of 
parameters) you simply point the URL to a server with an .xml configuration file. This is 
useful, for example, to change a reflector URL, set the audio and video rates, etc. when the 
VBrick appliances are behind a firewall and cannot be accessed remotely.
The VBrick reads the URL field (e.g. 
www.myserver.com/config.xml) via HTTP protocol and 
executes the script depending on the 
VBEXECUTE tag. If a VBEXECUTEFORCE tag is present in 
the .xml file (see example below), the script runs every time at the poll interval even if it has 
not changed. If a VBEXECUTEIFDIF tag is present the script runs only if it is different from the 
last executed file. One of these tags is required.
If the VBrick is in 
Edit mode, the script file will not run until the edit session is ended. The 
auto config script will run before any waiting IR scripts or external event scripts. In Edit 
mode, you can press Run Script to execute the script on demand. After a reboot, the VBrick 
checks for a script URL and will run the script immediately, regardless of the 
VBEXECUTE tag 
value.










