• In some time zones the configured time for cameras recording with VRM is
one hour off.
• Manual Recording in Operator Client for Local Storage and VRM starts recording for the
configured post-alarm time, for NVR cameras it starts recording until the manual recording button
is pressed again or until the configurable maximum manual recording time has elapsed.
• NVR Archive Player requires no logon. No permissions for audio and video can be checked.
• Permissions to export recording overrides restrictions to playback only time-sections of a camera.
• The date and time in emails sent upon alarms are in UTC time format.
• When calling up a camera through a decoder keyboard on an Allegiant monitor through Bosch
VMS, permissions are not considered.
• When configuring a Workflow alarm, do not use links containing an URL.
• When limiting access to video for certain schedules or the last N hours for Dual Authorization
groups, the value of the first logged on user is used.
• When permissions for cameras are removed, cameras shown in Image windows before the
permissions have been revoked must be closed manually.
• When the user of Configuration Client scans an existing VRM, the encoder names are renamed
to default BVMS names.
• When using Find Video By Event, alarm recordings triggered by users cannot be found directly.
You need to search for the general alarm recording and then sort by user.
• When using the Bosch VMS SDK to handle alarms,
o make sure to clear accepted alarms,
o if your application is disconnected from Bosch VMS, make sure to handle them after your
re-connected again,
o make sure to check the status of an alarm before you accept, un-accept or clear it.
• When using the Initial Device Scan to assign new IP addresses for new devices, make sure to
not configure duplicate IP addresses.