Specifications
Security Systems
Grasbrunn
05-February-2015
Page 29 of 38
o The supported Allegiant Master Control Software is 2.92.0.1
o Bosch VMS integrates with BIS version 3.0
• When activating a license on Windows 7 or Windows Server 2008, make sure that the network
adapters required for operation are active. When unplugging a network cable, these Operating
Systems deactivate the corresponding network adapter.
• When upgrading a Management Server, stop the Central Server service before starting setup.
• Upgrade is not working if Configuration Client is left open - close Configuration Client before
upgrade.
Resolved issues in version 4.5
MVS
• Fixed: Mobile devices cannot access playback of a disconnected camera.
Setup/Upgrade
• Fixed: Sometimes Bosch VMS 4.0.x could not be de-installed.
• Fixed: Mobile Video Service has not been updated during a Bosch VMS Upgrade.
• Fixed: Bosch VMS not un-installable after deinstallation of MVS.
• Fixed: Setup did not show in all cases what is installed on the computer.
• Fixed: Deinstallation of only VSG was not possible.
• Fixed: Empty error message box when trying to install Bosch VMS Operator Client on top of
CameoSDK installation.
• Fixed: After No Touch Deployment for Configuration Client is finished, a remote address did not
appear on Configuration Client Login window.
• Fixed: Update of MVS failed on installation of Video SDK
• Fixed: Cameo SDK cannot be installed after Operator Client.
Operator Client
• Fixed: Crash and restart of Operator Client's after forced configuration change during test with
nearly 100 Operator Clients.
• Fixed: Opening a playback VRM camera in the Operator Client leads to a crash if its IP address
is contained in the IP address of another device.
• Fixed: Bosch VMS 4.0 Operator Client crashing while displaying VCA overlay on multiple Image
panes.
• Fixed: BRS 8.10 ASF export did not work.
• Fixed: Preposition faulty when viewing in Bosch VMS from BRS 8.10.
• Fixed: Audio missing in ASF export.
• Fixed: Printings and snapshots in Operator Client could be distorted.
• Fixed: Decoder keyboard could lose connection during concurrent doming.
• Fixed: XP: Op Client showed wrong server states.
• Fixed: IntuiKey tree mode leads to keyboard failure under certain circumstances.
• Fixed: Operator Client freezes for about 30 seconds during shutdown in an Enterprise
Management System.
• Fixed: Assigning cameras in playback endurance test: memory rise and crash (under XP)
• Fixed: Panning a >7 x zoomed image in regular speed not possible with SD cameras.
• Fixed: Crash and restart of Operator Clients after forced config change (by file transfer service
problem)
• Fixed: Memory rise at long run 5x5 sequences with VCS + DIBOS cameras, any not connected
• Fixed: Operator Client could crash when switching from summertime to wintertime.