Specifications

Security Systems
Grasbrunn
05-February-2015
Page 17 of 38
Operator Client now supports a “Multi-view” feature when watching live. This
is particularly useful for displaying a 4K camera in multiple Image panes.
The operator can then adapt the image section in each Image pane by using focus and zoom.
The CPU load of Operator Client does not increase in this case. The reason is that the camera
image is decoded only once, the image sections in the Image panes are not decoded again. The
entire multi-view can be saved as a favorite.
The multi-view feature is not supported for Playback Mode. In Playback Mode, an Image section
of a camera is decoded for each Image pane. Displaying the recording of a 4K camera in multiple
Image panes can lead to severe performance issues.
The multi-view feature is not supported for transcoded videos.
When the connection of Operator Client to Management Server is reestablished after a period of
working in offline mode, all user events that occurred during offline mode, are transmitted to the
server. This is not valid for logon/logoff events. They are not logged during offline mode.
Management Server
Whenever you have two or more network addresses you need to make sure that the time server
entry in the Management Server configuration is set to the correct IP address.
When importing an old configuration file that was created with an earlier version of Bosch VMS,
event types that are new to Bosch VMS 5.0 will not be available until the configuration is
activated manually!
Web Client/IOS App
The operator permission for exporting video is not applied for exporting video with Web Client.
Hence, a user without permission to export video on Operator client can still export video from
the Web Client.
Calling up cameras on a DIVAR 700 using the MVS is under some rare circumstances not
always stable in playback
Web-Client works well with IE 11. It has also been tested with Firefox 30, Chrome 36 and Safari
7.0.5. These versions show some limitations in the PTZ functionality of an Image pane.
Routed access
Motion search is not supported over routed access.
Multi-site
Copying similar configuration files to several servers within an Enterprise Management System
environment, may lead to faulty indications of the server states in Operator Client. To avoid this,
please properly import the configuration files using the corresponding controls in Configuration
Client or Wizard.
Wizard
When changing network settings in Config Wizard, the Wizard will restart the computer.
Config Wizard applies the global default password also to the VSG, but only if it is allocated to
Pool 0.
SDK
CameoSDK test application: an unhandled exception is thrown when clicking "Disconnect"
button.
Barco Monitor Wall Transform N
New RCP+ Agent has been released for Bosch VMS 4.5.5 and Bosch VMS 5.0 to integrate the Barco
Transform N series. Barco RCP+ SDK Agent requires activation of multicast in all used cameras.
Known issues:
No multiple drag and drop support (sequences)