FIXED: Pre-Positions on VSG attached ONVIF cameras were not possible
in case of an alarm (server-side doming).
FIXED: Scan Wizard could crash when assigning encoders.
FIXED: The user could add unsupported encoder types to the VRM.
FIXED: Digital monitor wall now supports ONVIF cameras via VSG.
FIXED: Dome prepositions were not properly saved for Axis ONVIF dome.
FIXED: ASF Export was unreliable on a CameoSDK-only machine. Every second export failed.
FIXED: Operator Client: Selection of Image pane of a PTZ camera by an operator with PTZ
permissions was very slow.
FIXED: Server State Icons for the servers of an Enterprise system were not displayed correctly.
Tooltip showed correct states, the state-icons showed wrong states.
FIXED: Button to accept device configuration mismatch in Configuration Client did not look like a
button.
FIXED: Configuration Client crashed accidently, when assigning all scanned encoders (>200) to
a VRM.
FIXED: Pools and encoders could not be moved successfully from pool 0 to another.
FIXED: MVS sometimes used wrong computer name in case of changing it in the wizard at first
use of the box without restart.
FIXED: Management server went offline after upgrade when for multiple hours Operator Clients
with older software versions tried to reconnect.
FIXED: On a German system the setup dialog (where to select the features to install) was
scrambled, and it was not possible to select the VSG (Checkbox was hidden by "BVMS SDK"
option).
FIXED: CameoSDK: ObjectDisposedException was thrown from time to time when disposing
ICameoControl.UIControl.
FIXED: Instant playback in fast forward/backward mode: pause did not work for all cameras
types.
FIXED: After installation of Central Server, Configuration Client, Operator Client and MVS on a
blank Win7 machine MVS was not installed.
FIXED: Allegiant CCL Emulation for Command "MON+CAM": arguments were swapped Please
consider: This bug fix for Allegiant CCL emulation will cause problems for customers who rely on
the defective behavior of command MON+CAM. Instructions for customers want to reactivate the
former behavior (swapped parameters):
On the Management Server machine:
1) Stop the Management Server service.
2) Open BvmsCentralServer.exe.config.
3) Uncomment line <!--<add key="SetAllegiantCclCompatibleWithBVMS4x" value="true" />--> i.e.
remove <!-- and --> in this line.
4.) Save changed BvmsCentralServer.exe.config.
5) Start the Management Server service.
FIXED: G.711 audio from VG5 dome was noisy and audio level was too low in Operator Client
FIXED: Audio should be lip sync. Operator Client presented delayed audio from VG5 dome for
about 0,5 sec.