Installation Guide
Page 1 / 2
220523
1. Attach the mounting strap unit (A) to the outlet box by using two
mounting screws (B).
2.
Pull out the source wires from the outlet box. Make wire
connections using wire connectors (C) as follows:
• Connect the hot wire (usually black insulation) from
the fixture to the black wire from the power source.
• Connect the neutral wire (usually white insulation)
from the fixture to the white wire from the power source.
• Attach the fixture ground wire (usually green insulation
or bare wire) to the mounting strap unit (A) with the green
ground screw. Then, depending on local code, then
connect it to the house ground wire with the wire
connector (C).
Carefully put all of the wires back into the outlet box.
3.
Attach the canopy to the mounting strap
unit (A)
by inserting the
fixture mounting screws, and then secure it with two rubber pads
(E)
and two bolt nuts
(D)
.
4. Attach the shade to the socket, then secure it with the socket ring.
5. Install the bulb (not included). Check relamping label at socket area
or packaging for maximum wattage allowed .
ASSEMBLY AND INSTALLATION
INSTRUCTIONS
NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. READ AND SAVE THIS INSTRUCTIONS.
T0667
Hardware Package (included):
Turn off the power at fuse or circuit box.
Installation Steps
Turn on the power at fuse or circuit box.
Mounting Screw (B) Wire Connector (C)Mounting Strap Unit (A)
Bolt Nut (D) Rubber Pad (E)
Outlet Box
House Ground Wire
Wire Connector (C)
Mounting Strap Unit (A)
Green Ground Screw
Mounting Screw (B)
Fixture Wire
Fixture Mounting Screw
Fixture Ground Wire
Canopy
Bolt Nut (D)
Rubber Pad (E)
Socket
Shade
Socket Ring
Max.60W Type A Bulb
(not included)
WARNING: Turn off the main power at circuit breaker before installing fixture.
AVERTISSEMENT: Coupez la source d’alimentation principale au panneau