Installation Guide

191123
Assembly Kit
6193MM (1SET)
The following parts are available for re-order if damaged or missing.
Spare Parts List:
5. Gently place four smaller flat glasses into four sides of the interior frame into position
as shown in Fig.5. With one side locating into the slot of “S” clip, secure the flat
glasses by pressing the clips.(See Fig.3 & Fig.4)
6. Pull out the source wires from the outlet box. Make wire connections using wire
connectors (C) as follows:
• Connect the hot wire (usually black insulation) from the fixture to the black wire
from the power source.
• Connect the neutral wire (usually white insulation) from the fixture to the white
wire from the power source.
• Attach the fixture grounding wire (usually green insulation or bare wire) to the
mounting strap unit (A) with the green grounding screw (C), then connect it to
the house grounding wire with the wire connector (C).
Carefully put all of the wires back into the outlet box.
7. Attach the ceiling pan to the mounting strap unit (A) by inserting two fixture mounting screws, then secure it with the
bolt nuts (D).
8. Install bulbs (not included). See relamping label at socket area or packaging for maximum wattage allowed.
9. Restore the frame back to the ceiling pan using two set screw.
Fig. 5
Frame
Flat Glass
Flat Glass
Turn on the power at fuse or circuit
box.
Side Glass X 4
Bottom Glass X 1
10137CS
A
B
A: 11-1/2"
B: 6"
Mounting Screw (B)
Wire Connector (C)
Bolt Nut (D)
Mounting Strap Unit (A)
“S” Clip (E)
X 8