Installation Guide
141210
Page 2
Turn on the power at  fuse or circuit box.
   - Weave the fixture wires through the chain, collar and canopy.
6. Connect one end of the chain to the loop using a loop lock.
7. Connect the other end of the chain to the top loop using the other loop lock.
8. Thread the fixture wire and fixture grounding wire through the top loop, threaded pipe and mounting strap. 
9. Pull out the source wires from the outlet box. Make wire connections using wire nuts as follows:
     ---Connect the smooth-coated wire (marked) from the fixture to the black wire from the power source.
     ---Connect the ribbed-coated wire (unmarked) from the fixture to the white wire from the power source.
     ---Attach the fixture grounding wire to the mounting strap with the green grounding screw. Then connect it to the house 
         grounding wire with a wire nut.
    Carefully put the wires back into the outlet box. 
10. Attach the canopy to the mounting strap: insert the top loop through hole, then secure it by tightening collar.
11. Attach the candle tubes onto the sockets.
12. Install bulbs (not included). See relamping label at socket area or packaging for maximum allowed wattage.
13. Install the crystal drops(M,N) and pearl strands (O) as shown in diagram.
Mounting Strap (A)
Mounting Screw (B)
Green Grounding 
 Screw (C)
Hex Nut (D)
Wire Nut (E)
Canopy (G) 
Top Loop (H)
Collar (I)
Threaded Pipe (F)
Washer (J)
Loop Lock (K)
Chain (L)
Spare Parts List:
Assembly Kit
(5259MM)
(1 SET)
The following parts are available for re-order if damaged or missing. 
A: 10"
B: 16-1/2"
A
B
Crystal drop(M)
5067GS(12 SETS)
Crystal drop(N)
5068GS(1PC)
Pearl Strand(O)
5260CC(6 SETS)
Bobeche(Q)
9690CE(1PC)
Bottom Glass(P)
9691CE(1PC)