Installation Sheet

PAGE: 2 / 5
Fig.9
Fig.9a
Antenna
DIP Switch
Transmitter
Receiver
There is a frequency-setter respectively in
the transmitter and receiver. This "DIP
Switch" is a 4 key unit (Fig. 14). All keys
were set at "ON" position in the beginning.
Set the keys to a different code. Make sure
the same numbered keys are switched "ON"
for both DIP Switches (Fig. 14a). Take note
that the "ON" position may have different
orientation in each.
Code example:
1-ON 2-OFF 3-ON 4-OFF
on both DIP Switches.
Fig.10
Move Ground Wires (a), Outlet Box wires (b), and
Motor Wires (c) away from the center of the Hanger
Bracket. Then slide Receiver through Hanger
Bracket as shown, Antenna end first, until it is
centered. Finally, cut Motor Wires (c) to length
needed for connections.
Antenna
Receiver
Hanger
Bracket
a.
b.
c.
Fig.11
Hanger
Bracket
Hanger
Ball
Receiver
1.
4.
5.
6.
2.3.
Antenna:
DO NOT CUT
OR SPLICE
Make wire connections:
1) The Motor white wire to the white "To Motor N" wire from
Receiver with a wire nut.
2) The Motor black wire to the black "To Motor L" wire from
Receiver with a wire nut.
3) The Motor blue wire to the blue "For Light" wire from
Receiver with a wire nut.
4) The white wire from Outlet Box to the red "AC in N" wire
from Receiver with a wire nut.
5) The black wire from Outlet Box to the red "AC in L" wire from
Receiver with a wire nut.
6) The ground wire from Outlet Box to the green ground wire
from the Hanger Ball and the green ground wire from the
Hanger Bracket with a wire nut.
Make sure all of wire nuts are connected firmly.
*** Tuck all wire nuts and wires carefully up into the Outlet Box,
EXCEPT antenna, which should remain outside Outlet Box.
Fig.12
Attach the loop at the end of the safety cable to the ceiling surface,
then secure it with a flat washer and dry wall screw. Make sure the
flat washer and dry wall screw are covered by the fan canopy.
Flat Washer
Safety Cable
Dry Wall Screw
Ceiling
Hanger Bracket
Ceiling Joist
Wood Member
(2" x 4" Approx.)
Junction Box
090406
F A N C OF A N C O