Table I–1 (Cont.): Model 300 Console Error Messages Indicat-
ing Halt
Error Message Meaning
?11 ACV or TNV during KSP not valid. An access violation or translation-not-
valid error occurred while handling an-
other error condition.
?12 Machine check during machine check. A machine check occurred while han-
dling another error condition.
?13 Machine check during KSP not valid. A machine check occurred while han-
dling another error condition.
?19 PSL <26:24>= 101 during interrupt
or exception.
An exception or interrupt occurred while
on the interrupt stack but not in ker-
nel mode.
?1A PSL <26:24>= 110 during interrupt
or exception.
An exception or interrupt occurred while
on the interrupt stack but not in ker-
nel mode.
?1B PSL <26:24>= 111 during interrupt
or exception.
An exception or interrupt occurred while
on the interrupt stack but not in ker-
nel mode.
?1D PSL <26:24> = 101 during REI. An REI instruction attempted to re-
store a PSL with an invalid com-
bination of access mode and inter-
rupt stack bits.
?1E PSL <26:24> = 110 during REI. An REI instruction attempted to re-
store a PSL with an invalid com-
bination of access mode and inter-
rupt stack bits.
?1F PSL <26:24> = 111 during REI. An REI instruction attempted to re-
store a PSL with an invalid com-
bination of access mode and inter-
rupt stack bits.
I–2 VAX 6000 Series Owner’s Manual