Owner`s manual
Table H–3: Console Error Messages for Models 500 and 600
Error Message Meaning
?0104 Filename format error. Period and semicolon characters are im-
properly used within the filename speci-
fied for a MOP boot.
?0105 Illegal character(s) in filename. For filename specified in a MOP boot.
?0106 Filename cannot contain nested blanks or
tabs.
For filename specified in a MOP boot.
?0107 Filename can be no longer than 16 char-
acters.
For filename specified in a MOP boot.
?0111 Microcode power-up self-test failed in
DC595.
Model 500 CPU chip failed its mi-
crocoded self-test.
?011E Uncorrectable memory errors discovered -
long memory test must be performed on node n
Memory array in node n contains an un-
correctable error. The console must per-
form a full test to locate all thefailing loca-
tions.
?0120 Unsupported memory module found, will
not be configured.
One or more MS62A memory mod-
ules are installed but will not be used.
Only MS65A memory modules are com-
patible with Model 500 and higher.
?0121 Patch command no longer implemented—
use the Diagnostic utility EVUCA.
An invalid PATCH command was is-
sued; use the EVUCA program to up-
date the EEPROM.
Table H–4: Console Error Messages Unique to Model 600
?0201 One or more power-up tests have been by-
passed.
A test normally run by the proces-
sor at power-up has been bypassed.
?0203 Hardware compatibility group mismatch—
secondary/primary: x/y.
Indicates hardware version mismatches
between the primary CPU and an indi-
cated secondary CPU.
?0205 Error locating ROM boot code, run diag-
nostics.
Indicates a hardware problem read-
ing the CPU’s ROM code.
?0206 EEPROM in error or contains unsup-
ported PCS, processor disabled.
Indicates an out of rev or faulty EEP-
ROM image. Use the EVUCA pro-
gram to upgrade the EEPROM for the in-
dicated CPU.
H–12 VAX 6000 Series Owner’s Manual